AI232 Version 9.6x User’s Guide

Link Configuration: RTS/DTR Lead Control Configuration

RTS disconnect state—Sets the RTS disconnect state to one of the following options:

zOn—Sets RTS to on when the link disconnects.

zOff—Sets RTS to off when the link disconnects.

zToggle—Makes RTS pulse when the link disconnects. The pulse polarity is opposite to the sense specified for the connected state.

Menu Item Type

Toggle

Link Type Availability

Async and AsyncPPP

Configuration in the AI198 Menu System

1.For an asynchronous or asynchronous PPP link, access menu 4.2.14.12.13.

2.For 03*RTS connect state, enter 3 to select ON, OFF, or FLOW CONTROL. The default is ON.

3.For 04*RTS disconnect state, enter 4 to select ON, OFF, or TOGGLE. The default is OFF.

This example displays 03*RTS connect state set to FLOW CONTROL and 04*RTS disconnect state set to TOGGLE.

>4

 

 

Menu 4.2.14.12.13

01*DTR connect state---------------------------------------------------------

ON

02*DTR disconnect state (On, Off, Toggle)-----------------------------------

OFF

03*RTS connect state (On, Off, Flow Control)-----------------------

FLOW CONTROL

04*RTS disconnect state (On, Off, Toggle)--------------------------------

TOGGLE

 

 

Configuration in the AI232 Local Menu System

1.Access the Async Link Menu or AsyncPPP Link Menu.

2.Select RTS/DTR Lead Control Options Menu. The RTS/DTR Lead Control Options Menu appears.

3.For RTS connect state, select On, Off, or FlowControl. The default is On.

4.For RTS disconnect state, select On, Off, or Toggle. The default is Off.

5-47

Page 127
Image 127
Kentrox AI232 manual Flow Control