AI232 Version 9.6x User’s Guide

Link Configuration: General Link Properties Configuration

This example displays 01 Link number set to 3.

>1,3

 

 

Menu 4.2.14.12

01 Link Number (1-32)

--------------------------------------------------------03

 

 

Configuration in the AI232 Local Menu System

1.Access the Link Menu.

2.For Link to configure, enter the link number. The default is 1. This example displays Link to configure set to 3.

Async Link Menu

Link to configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Link State

Description

This menu item enables or disables a link.

Menu Item Type

Toggle

Link Type Availability

Async, AsyncPPP, and ModMux

Configuration in the AI198 Menu System

1.Access Menu 4.2.14.12.

2.For 04*Link state, enter 4 to select Enabled or Disabled. The default is Enabled.

This example displays 04*Link state set to Disabled.

>4

 

 

 

 

Menu 4.2.14.12

01

Link Number (1-32)--------------------------------------------------------

03

02*Link Type (Async, AsyncPPP, ModMux)---------------------------------

Async

03

Link Description------------------------------

Async link 3

04*Link state (Enabled, Disabled)--------------------------------------

Disabled

 

 

 

Configuration in the AI232 Local Menu System

1.Access the Link Menu.

2.For Link state, select Enabled or Disabled. The default is Disabled.

5-21

Page 101
Image 101
Kentrox AI232 manual Link State, This example displays 01 Link number set to, This menu item enables or disables a link