AI232 Version 9.6x User’s Guide

Link Configuration: Disconnect Options Configuration

3.For 05*Inactivity Timer enabled when link receives call, enter 5 to select ON or OFF.

The default is OFF.

4.For 06*Inactivity Timer resets on incoming characters from destination, enter 6 to

select ON or OFF. The default is ON.

This example displays:

z04 Disconnect inactivity timer set to 236

z05*Inactivity Timer enabled when link receives call set to ON

z06*Inactivity Timer resets on incoming characters from destination set to OFF.

>6

 

 

 

Menu 4.2.14.12.12

01 Disconnect

when DSR off--------------------------------------------------

N/A

02*Disconnect

when DCD off--------------------------------------------------

OFF

03*Disconnect

when a break character is received----------------------------

ON

04 Disconnect

inactivity timer (0 - 32767 s, 0 = disabled)----------------

00236

05*Inactivity

Timer enabled when link receives call-------------------------

ON

06*Inactivity

Timer resets on incoming characters from destination----------

OFF

 

 

 

Configuration in the AI232 Local Menu System

1.Access the Async Link Menu.

2.Select Disconnect Options Menu. The Disconnect Options Menu appears.

3.For Disconnect inactivity timer, enter the timer value. The default is 0.

4.For Inactivity Timer enabled when link receives call, select On or Off. The default

is Off.

5.For Inactivity Timer resets on incoming characters from destination, select On or

Off. The default is On.

This example displays:

zDisconnect inactivity timer set to 367.

zInactivity Timer enabled when link receives call set to On.

zInactivity Timer resets on incoming characters from destination set to Off.

Disconnect Options Menu

 

 

Link being configured

. .

3

Disconnect when DCD is off

On

[Off]

Disconnect when a Break character is received

[On]

Off

Disconnect inactivity timer (0 - 32767s, 0 = disabled)

.. 367

Inactivity Timer enabled when link receives call

[On]

Off

Inactivity Timer resets on incoming characters from destination

On

[Off]

5-13

Page 93
Image 93
Kentrox AI232 manual Select on or OFF. The default is on This example displays, Is Off