AI232 Version 9.6x User’s Guide
AI232 Commands: link
8-64
link
Description
This command is used to:
zForce a serial link to connect or disconnect
Note: When this command is used to disconnect a serial link, all calls are torn
down. The serial link does not come back online until command link
start is issued.
Important: If you are connected to the AI232 shell using a serial port, remember
not to disable that port or else loss of connectivity will result.
zRestart a link, which is a stop followed by a start
zShow a configuration summary for a link or range of links.
Command Types
shell and winslc
Formats
For the shell command:
link {
link_range
| * } { start | stop | restart }
For the winslc command:
winslc
baseport
link {
link_range
| * } { start | stop | restart }
Parameters
link_range
Defines a link or range of links. Valid values are 1 to 32. Individual
values are separated by commas (,) and hyphens (-). For example,
1,4-6 specifies links 1, 4, 5, and 6.
Note: This parameter applies to any action the user is trying
perform (start, stop, restart, or show information).
*Specifies all links.
start Enables the serial links.
stop Disables the serial links.
restart Restarts the serial links.
baseport
Defines the baseport number for AI232.