AI232 Version 9.6x User’s Guide
System Configuration: General System Properties Configuration
4-3
Note: You can include multiple characters with delays between each in the break
sequence. For example, <c>^[1,5]x[0,9]k is a valid entry.
Menu Item Type
Data
Configuration in the AI198 Menu System
1. Access Menu 4.2.14 pg 2.
2. From Menu 4.2.14 pg 2, enter 3, and the desired destination menu break
sequence. The maximum length is 44 characters. The default is <c>^[1,5]x.
This example displays item 03 Destination Menu Break Sequence configured as
<c>^[2,6]x.
delay_end
Defines the amount of time (in seconds) before which
you must enter the next character. Valid values are
integers from 1 to 9.
Note: If you do not enter the next character within
the configured time frame, then both the
attention_keystroke
and
next_character
values are treated as data and forwarded.
next_character
Defines the next character in the sequence. Valid
values are:
z<
x
> where
x
represents the decimal ASCII value
of the keystroke. For example, enter <9> to
represent the TAB key.
z<c>
x
where <c> represents the CTRL key and
x
represents the actual key name. For example,
enter <c>^ to represent CTRL+SHIFT+6.
z<c><
x
> where <c> represents the CTRL key and
x
represents the decimal ASCII value of the
actual key name. For example, enter <c><9> to
represent CTRL+TAB.
>3,<c>^[2,6]x
Menu 4.2.14 pg 2
01*10 Base T Ethernet-------------------------------------------------------OFF
02+Radius Configuration Menu
03 Destination Menu Break Sequence-----------------------------------<c>^[2,6]x