AI232 Version 9.6x User’s Guide

AI232 Commands: staeia

staeia

Description

This command displays the status of the EIA leads.

Command Types

shell and winslc

Formats

For the shell command:

staeia { link_range * }

For the winslc command:

winslc baseport staeia { link_range * }

Parameters

link_range Defines a link or range of links. Valid values are 1 to 32. Individual values are separated by commas (,) and hyphens (-). For example, 1,4-6specifies links 1, 4, 5, and 6.

*Specifies all links.

baseport Defines the baseport of AI232.

Examples

This example displays the status of the EIA leads for links 1 to 5.

[232] staeia 1-5

 

 

 

 

 

Link Type

Status

 

IN

 

OUT

 

 

 

DSR

DCD

CTS

DTR

RTS

1: ASY

Disabled

 

 

 

 

 

2: ASY

Enabled

-

-

-

+

+

3: ASY

Enabled

-

-

-

+

+

4: ASY

Enabled

-

-

-

+

+

5: ASY

Disabled

 

 

 

 

 

[232]

 

 

 

 

 

 

 

 

 

 

 

 

 

Column

Description

 

 

DSR

DSR is an incoming EIA lead control signal. The plus symbol (+)

 

indicates that this lead is asserted. The minus symbol (-) indicates that

 

the lead is negated.

 

 

8-89

Page 261
Image 261
Kentrox AI232 manual Staeia, This command displays the status of the EIA leads, Lead is negated