Wayne-Dalton 341785 installation instructions End Brackets, Center Bearing Bracket

Models: 341785

1 34
Download 34 pages 26.25 Kb
Page 22
Image 22
End Brackets

 

 

14

End Brackets

 

 

 

Tools Needed:

NOTE: Right and left hand is always

Power Drill

determined from inside the garage

looking out.

 

7/16” Socket

End bearing brackets are right and left.

Driver

Align bottom edge of left end bracket

 

 

with the top edge of the flagangle.

 

Maintaining this alignment, also align

 

the right edge of the end bracket with

 

the right edge of the flagangle.

 

Secure end bracket to the jamb using

 

(3) 5/16” x 1-5/8” lag screws as shown.

 

Repeat for the other side.

 

 

left hand end Center Bearing Bracket bracket

top section

(3) 5/16” x 1-5/8”

LAG SCREWS

left hand end

bracket

top section

15

Center Bearing Bracket

Mounting surface

 

 

 

 

 

 

Tools Needed:

Measure to locate the center of the door

Equal distance

 

and mark a vertical pencil line on the

 

 

 

 

Power Drill

mounting surface above the door, to

Center of

Center bearing

 

indicate the center line of the door. Then,

end bearing

bracket

7/16” Socket

measure from the center of the bearing, in

bracket

Vertical line

 

Driver

one of the end bearing brackets, DOWN to

 

 

the top of the door. Using that dimension,

 

 

 

Horizontal line

 

 

measure UP from the top of the door

 

Level

 

 

and mark a horizontal pencil line on the

 

 

 

 

 

Tape Measure

mounting surface, intersecting the vertical

 

 

pencil line. Now align the edge of the center

 

 

 

 

 

Pencil

bearing bracket along the vertical pencil

(1) 5/16” x 1-5/8” lag screw

Center

line on the mounting surface. Center the

bearing

 

bearing bracket on the horizontal line. This

Mounting

bracket

1/4” Torx Bit

will ensure the torsion tube is level between

 

surface

 

 

the center and end bearing brackets. Attach

 

 

 

 

 

the center bearing bracket, in this location,

Horizontal line

 

 

to the mounting surface, using (2) 5/16”

 

 

 

 

 

x 1-5/8” lag screws and (1) 5/16” x 2”

 

 

 

tamper-resistant lag screw.

 

 

 

IMPORTANT: Use the 5/16” x 2” tamper-

 

 

 

resistant lag screw ONLY if mounting

(1) 5/16” x 1-5/8” lag screw

 

 

surface mounted over masonry.

 

 

 

Tamper-resistant lag screw MUST be

(1) 5/16” x 2”

 

 

attached through the bottom hole

 

 

Tamper-resistant lag

 

 

of the center bearing bracket.

Vertical

 

screw

 

 

 

 

 

line

22