Photoelectric Safety Sensor

Photoelectric Safety Sensor

Installation Continued

Uncoil wires from photoelectric sensors and route wires up garage wall and along door header towards the right side of the opener. Route wires above torque tube and tack wires in place with insulated staples (not supplied). Take care to run wires in a location where they will not interfere with the operation of the door and do not staple through wire.

Connect photoelectric sensors to the opener terminal block in right side of the opener. Separate wire ends and strip about 1/2” of insulation off each of the wire ends. Insert a 3/32” (2,5 mm) max. width flathead screwdriver into the lower hole #1 of the terminal block. Twist screwdriver to open wire clamp in up- per hole #1 of terminal block. Insert both sender and receiver solid white wires into upper hole #1 until the wires bottom out and release screwdriver tension. In- sert both sender and receiver wires (white with black strip) into upper hole #2 by the same process on lower hole #2 of terminal block. Once wires are connected install jumper on to the left most set of pins labeled “PE”, located on the front of the opener.

IMPORTANT! Keep sender/receiver wires away from moving members.

Be sure to observe polarity. Pull on external wires to test for secure connection. Check that the wires are stapled in place and staples have not cut wire insula- tion.

WIRE ROUTING

INSERT SENDER

WIRES

INSERT

RECEIVER

WIRES

RIGHT HAND SIDE

VIEW OF OPENER

INSERT WIRES INTO

UPPER HOLES

OPENER

SOLID

 

 

WHITE WIRES

 

 

WHITE WIRES

INSERT SCREW-

 

WITH BLACK

 

DRIVER INTO

 

STRIPES

 

LOWER HOLES

 

 

 

SENDING IR LED

 

VIEW OF THE OPENER

JUMPER INSTALLED

 

ON PINS “PE”

 

FROM THE FRONT

 

 

 

 

20

 