Wall Station Operation:

Wall Station Operation:

Momentarily pressing the up/down button activates

 

the door. If an out-of-balance condition causes the

 

door to stop while opening or reverses the door while

 

closing, applying constant pressure to the up/down

 

button until the door is fully open or closed will allow

 

the opener to move the door in this condition until the problem is

UP/DOWN

corrected. See Troubleshooting.

If a severe out-of-balance condition causes the door to stop while closing, the door can ONLY be lowered by the following proce- dure:

Multiple activations of the up/down button will lower the door incrementally. Continue this process until the door is completely closed.

LED

TIMER service person immediately. PET

LIGHT

PROFILE

Manual backgroundWARNING FAILURE TO MAKE ADJUSTMENTS/REPAIRS, COULD RESULT IN SEVERE OR FATAL INJURY.

Manual backgroundWARNING DO NOT USE THE EMERGENCY DISCONNECT TO LOWER THE DOOR. THE DOOR COULD FALL RAPIDLY CAUSING A SEVERE OR FATAL INJURY.

The severe out-of-balance condition must be corrected before the door can be reactivated: Contact a qualified

service person immediately.

Momentarily pressing the light button turns on the light fixture. The light fixture will remain on until either the light button is pressed again or the door is activated. The light fixture automatically turns on with a door activation and remains on for five minutes thereafter. Pressing the light fixture button before the five minutes has elapsed will turn off the light fixture. While the door is in motion, the light button functions identically as the up/down button, stopping or reversing the door immediately.

Momentarily pressing the timer button causes a delayed activation of a stationary fully open door. The opener will signal seven beeps (approx. 8 seconds) then beep constantly for two seconds prior to closing the door. Allow enough time to exit the garage when the opener is in the timer mode. Pressing any button, except for the profile button while the opener is beeping cancels the timer mode. NOTE:

The timer feature will only function with the door in the full open position. Pressing the timer button with a stationary door in any other position will cause the opener to beep four times and the door will not be activated. While the door is in motion, the timer button functions identically as the up/down button, stopping or reversing the door immediately.

Pressing the pet button opens a closed door to a preset position between eight and thirty inches above

the floor, allowing pets to enter and exit the garage without the door being fully open. The door must

Manual background be fully closed to activate the pet open feature. Pressing the pet button with a stationary door in the pet open position will cause the door to close. Pressing the up/down button while the door is in the pet position will cause the door to open. While the door is in motion, the pet button functions identically to the

up/down button, stopping or reversing the door immediately. The pet feature allows for custom setting of the pet position door height. See Step 27: Custom Settings.

NOTICE: A door in the “pet position” (open 8-30 inches) is not locked and should not be used as a secured door position.

Pressing and holding the profile button for five (5) seconds will initiate the “Install Routine”. Refer back to Step 24 for complete Install Routine instructions and functions. The wall station LED will

light while any wall station button remains pressed. See Maintenance section for battery replacement. NOTE: Refer to Step 23 for wall station programming instructions.