Manually position the door to the desired pet opening height (between 8” and 30” above ground) and return disconnect handle to the motor operated position.
2.Simultaneously depress the pet and up/down buttons on the wall station. The opener will beep once. The pet button is now programmed to automatically open the door to this custom height.
NOTE: The opener will NOT accept programmed pet lock position if door is below 8” or higher than 30”.
NOTE: Activation of the normal install routine will reset the pet position to the default eight inch target height. For use of the pet button see Operation section.
Step 28: Photoelectric Obstruction Sensor Test
Starting with the door in the fully open |
|
|
|
|
|
|
|
|
|
|
|
position, place a 6” high object on the |
|
|
|
|
|
|
|
|
|
|
|
floor progressively one foot from the left |
|
|
|
|
|
|
|
|
|
|
|
side of the door, center of door and one |
|
|
|
|
|
|
|
|
|
|
|
foot from the right side of the door. In |
|
|
|
|
|
|
|
|
|
| 12” |
each position, activation of the opener |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
with the wallstation up/down button |
|
|
|
|
| 6” | |||||
|
|
|
|
|
|
|
|
|
|
| |
should cause the door to move no more |
|
|
|
| 12” | ||||||
than one foot, stop and then reverse to |
|
|
|
| |||||||
|
|
|
| ||||||||
fully open position. The same 6” high |
|
|
|
|
|
|
|
|
|
|
|
object when placed on the floor, while |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
door is closing, should also cause the door to reverse. |
|
|
|
|
|
|
|
WARNING WHEN PERFORMING THIS PART OF THE TEST, DO NOT PLACE YOURSELF UNDER DESCENDING DOOR, OR SEVERE OR FATAL INJURY MAY RESULT.
WARNING IF THE OPENER DOES NOT RESPOND PROPERLY, OR FAILS THESE TEST, HAVE A QUALIFIED SERVICE PERSON MAKE NECESSARY ADJUSTMENTS/REPAIRS. FAILURE TO MAKE ADJUSTMENTS COULD RESULT IN SEVERE OR FATAL INJURY.
Step 29: Contact Obstruction Test
After installing the opener, the door must reverse when it: contacts a
1. Using the wall station, activate the door to the fully open position .
2.Place a 2 x 4 board laid flat on the garage floor under the door path.
3.Activate the door to the closed position with the
wallstation; upon contacting a solid object, the door will stop, then reverse direction within two seconds and travel to the full open position.
If the door does not respond to the required tests, remove 2 x 4 and repeat install routine making sure the door is in the fully closed position prior to activation. If problem persists contact Wayne Dalton Customer Service (888)
WARNING IF OPENER DOES NOT RESPOND PROPERLY AND FAILS EITHER OF THE TWO TESTS (28 AND 29), DOOR MAY CAUSE A SEVERE OR FATAL INJURY. HAVE A QUALIFIED
27