Step 21: Securing the Opener

Step 21: Securing the Opener

With the emergency disconnect still in the manual door operated position: Manually raise the door to the full upward position. Then, manually lower the door to the full closed position verifying freedom of move- ment and good door balance.

Tighten both 1/4-20 flange nuts, securing the opener to the support bracket.

NOTE: Good door balance and freedom of movement are critical to the safety and perfor- mance of the door opener. If door is very heavy to lift or if springs are too tight making door hard to close or if door sticks or binds in the track, now is the time to correct it.

1/4-20 FLANGE NUTS

SUPPORT BRACKET

Step 22: Photoelectric Safety Sensor Alignment

IMPORTANT! - This infrared safety sen-

 

IN

 

FIG. 1

IN

 

sor sends an invisible beam of light from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the sending unit to the receiving unit across

 

 

 

 

 

 

 

 

 

the pathway of the door. The door opener

 

 

 

 

 

 

 

 

 

will not operate until the safety sensor is

 

 

 

 

Top View

 

 

 

connected to the power unit and properly

 

 

 

 

Align in Center

 

 

 

aligned. If the invisible beam of light is ob-

 

 

 

 

 

 

 

 

 

 

 

(In/Out)

 

 

 

 

OUT

 

OUT

 

structed, an open door cannot be closed by

 

 

 

 

 

1/4-20 CARRIAGE BOLTS

 

the transmitter or a momentary activation of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 2

 

 

 

the wall mounted push button. However, the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

door may be closed by holding your finger

 

 

 

For this adjustment bend bracket at

 

 

 

on the wall push button (constant pressure)

 

 

 

 

 

 

 

 

 

 

wall mount

 

 

 

 

until the door travels to a fully closed posi-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tion. The safety sensors must be aligned by

 

 

 

 

Top View

 

 

 

moving the sending and receiving units in

 

 

 

 

Align in Center

 

 

 

or out (see Fig. 1) until the alignment light

 

 

 

 

 

 

 

 

 

on the receiving unit comes on. The

 

 

 

 

 

 

 

 

 

1/4-20” carriage bolt can be loosened to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

move the unit in or out, as required. If you have difficulty aligning beams, check that both brackets are mounted at the same height and remount if necessary. Additional minor adjustments can be made by lightly bending the mounting brackets (see Fig. 2).

Step 22: Photoelectric Safety Sensor AlignmentManual backgroundWARNING FAILURE TO MAKE ADJUSTMENTS COULD RESULT IN SEVERE OR FATAL INJURY.

Once the alignment light comes on, tighten all bolts and mounting screws. Finish securing all wire making sure not to break or open any of the conductors. Loop and secure any extra wire.