MOTOR

NOTE: The first wall station command, after programming, will only move the door through a six-inch up/down cycle. Normal door operation will occur on the second usage of the wall station.

NOTE: The opener can be activated by up to six remote control devices (including wall sta- tion, transmitter, and keyless entry devices.) If a seventh control is programmed, the first of the programmed controls will be overridden and will no longer activate the opener.

CAUTION: For safety reasons, manually disconnect the opener from the door using the

emergency disconnect handle prior to erasing remote controls. To clear programming of all remote control devices, press and hold the opener’s program button for approximately ten seconds. When the opener beeps three times, all remote controls are erased.

MOTOR

OPERATED

POSITION

Step 24: Install Routine

The install routine automatically sets the door open and close limits and calibrates obstruction sensing. During install routine, the door will move up and down twice. Always keep a moving door in sight and away from people and objects until it is completely closed.

Step 24: Install RoutineUP/DOWNWARNING TO AVOID INJURY, NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR!

UP/DOWN

BUTTON

PROFILE

BUTTON

NOTE: If no obstructions interfere with the door when manually opened and closed, proceed to Step 24 a. However, if an object such as a ceiling beam obstructed the door from opening completely, set a custom upper limit during the install routine, Step 24 b.

NOTE: The door must be in its fully closed position and the disconnect handle must be in the motor operated position (upper position) to initiate the install routine.

Step 24 a: Install routine with standard upper limit

Press and hold the profile button for five (5) seconds. The opener will beep twice, indicating the activation of the install routine, release the profile button. The door will now move to the full open position and stop. Then, the door will close completely. Next, the door will go through one more up/down cycle. Once this is complete, the door limits are set and the installation is complete.

Step 24 b: Install routine with custom upper limit

Press and hold the profile button for five (5) seconds. The opener will beep twice, indicating the activation of the install routine. When the door moves to the desired height, at least four feet off the ground, press the up/down button on the wall station. The door will stop and then close completely. Next, the door will go through one more up/down cycle. Once this is complete, the door limits are set and the installation is complete. Alternately: After an install routine has been completed, the door can be disconnected and manually moved to the desired upper limit. Reconnect door and initiate a new install routine from the new upper position.