Operating Instructions and Parts Manual | Shallow Well Jet Pump |
Manual de instrucciones de operación y piezasModelos para pozos profundos
General Safety Information (Continued)
16.Do not attempt repairs to the electric motor. All repairs to the motor must be completed at a licensed or certified electrical motor repair shop.
Do not touch an
! WARNING operating motor. Modern motors are designed to operate at high temperatures.
17.Avoid kinking electrical cord and protect from sharp objects, hot surfaces, oil and chemicals. Replace or repair damaged or worn cords immediately.
Disconnect power
! WARNING and release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected application of power.
18.Keep fingers and foreign objects away from ventilation and other openings. Do not insert any objects into the motor.
Risk of electric ! WARNING shock! Never
connect the green (or green and yellow wire) to a live terminal!
19.To reduce the risk of electrical shock, the pump should be plugged directly into a properly installed and grounded
Grounded
Pin
TESTRESET
Figure 1 | Grounded Outlet |
21.Use only
22.Use wire of adequate size to minimize voltage drop at the motor.
Do not handle ! DANGER pump or pump
motor with wet hands, when standing on a wet or damp surface or when standing in water. Fatal electrical shock could occur.
Pump motor is
! WARNING equipped with an automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading because of operating pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor connections or defective motor or pump.
Pre-Installation
WATER SUPPLIES
The water supplies illustrated in Figure 12 are possible sources for water. These water supplies can be divided into two categories:
SURFACE WATER
Water from a lake, stream, pond and cistern. This water is usually not fit for human consumption, but may be suitable for washing, irrigation or other household uses.
GROUND WATER
Water found in the water bearing stratum at various levels beneath the earth. Of all the fresh water found on earth only 3 percent is found on the surface and 97 percent is underground.
TANKS - CONVENTIONAL STORAGE
The function of the tank is to store a quantity of water under pressure. When full, the tank contains approximately 2/3 water and 1/3
compressed air. The compressed air forces the water out of the tank when a faucet is opened. An air volume control automatically replaces air lost or absorbed into the water. The usable water, or drawdown capacity, of the tank is approximately 1/6 of the tanks total volume when operated on a “20- 40” pressure setting (Figure 2).
TANKS - PRECHARGED STORAGE
| Air Volume |
| Control |
| Bladder |
Conventional | Precharged |
Tank | Tank |
Figure 2 - Conventional & Precharged
Storage Tanks
A precharged storage tank has a flexible bladder or diaphragm that acts as a barrier between the compressed air and water. This barrier prevents the air from being absorbed into the water and allows the water to be acted on by compressed air at initially higher than atmospheric pressures (precharged). More usable water is provided than with a conventional type tank. Precharged tanks are specified in terms of a conventional tank. For example, a 20 gallon precharged tank will have the same usable water or drawdown capacity as a 40 gallon conventional tank, but the tank is smaller in size (Figure 2).
PRESSURE SWITCH
The pressure switch provides for automatic operation. The pump starts when pressure drops to a
Para Piezas de Repuestos, Llame al 1-800-237-0987
Sírvase proporcionar la suguiente información: | Puede escribirnos a: |
|
| ||||
- Número de modelo | Wayne Water Systems |
|
| ||||
- Número de serie (si tiene) | 101 Production Drive |
|
| ||||
- Descripción y número de repuesto como se muestra | Harrison, OH 45030 U.S.A. |
|
| ||||
en la lista de repuestos |
|
|
|
|
| ||
|
| 1 |
|
|
|
|
|
|
| 2 |
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
| 4 |
|
|
|
|
|
|
| 6 | 7 |
|
| 12 |
|
|
|
|
|
|
| ||
|
| 5 |
|
|
|
|
|
|
|
| 9 | 8 |
|
|
|
|
|
|
| 10 | 11 | 13 |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
| 16 |
|
|
|
|
|
|
|
| 17 |
|
|
| 14 |
|
|
|
|
|
|
| |
|
|
|
|
|
| 15 |
|
No. de |
| Para Los Modelos |
|
| |||
Ref. |
| Descripción | Ctd. | ||||
1 |
| Motor | 1 | ||||
2 |
| Tornillo | 4 | ||||
3 |
| Placa de sellado | 1 | ||||
4 | • | Empaquetadura cuadrada de caucho para anillo | 1 | ||||
5 | • | Ensamblaje de sello del eje | 56393 | 56393 |
| 56393 | 1 |
6 |
| Impulsor | 1 | ||||
7 |
| Difusor | 1 | ||||
8 |
| Tornillo | 2 | ||||
9 | • | Anillo en o | 15557 | 15557 |
| 15557 | 1 |
10 |
| Venturi | 1 | ||||
11 |
| Boquilla | 15672 | 15672 |
| 15672 | 1 |
12 |
| 19,1 mm (3/4”) Tapón de cebado | 15921 | 15921 |
| 15921 | 1 |
13 |
| Voluta | 1 | ||||
14 |
| 6,4 mm (1/4”) NPT Tapón de cebado | 1 | ||||
15 |
| 3,2 mm (1/8”) NPT Tapón de cebado | 1 |
20.Where a
CHART 1 - JET PUMP/TANK ASSEMBLIES
|
|
| Air Volume | |
|
|
| Control | |
|
| Type | Required | |
|
|
|
|
|
| Well X | Precharged | No | |
|
|
|
|
|
| PCA | Precharged | No |
|
|
|
|
|
|
| 12P & 30P Horizontal | Conventional | Yes |
|
|
|
|
|
|
| FX Horizontal | Precharged | No |
|
|
|
|
|
|
17 | Base | 1 | |||
19 | Presostato | 1 | |||
• | Juego para reparaciones (Incluyes #4, 5 y 9) | 1 |
www.waynewatersystems.com
2
31 Sp