Operating Instructions and Parts ManualShallow Well Jet Pump
Manual de instrucciones de operación y piezas | Modelos para pozos profundos |
Installation |
| Prime |
| 4. If necessary, precharge with an air | |||
|
|
|
|
| |||
(Continued) |
|
| Plug |
| pump to 28 - 30 psi on 1/2, 3/4 and 1 | ||
|
|
| HP pumps. |
| |||
| Pressure |
|
|
| |||
NOTE: A packer type foot valve can be |
| Air | 5. Slope the horizontal pipes upward | ||||
Switch |
| ||||||
installed in the well (Figure 3, |
|
| Volume | toward the pump to prevent | |||
Illustration B). This type of foot valve |
|
| Control | trapping air. If the horizontal | |||
|
| Tubing | |||||
allows the well to be filled with water |
|
| distance exceeds 25 feet, see Chart | ||||
|
|
| |||||
when priming and makes the inlet pipe |
|
|
| 2 for the recommended pipe size. | |||
much easier to test for leaks. Follow |
|
|
|
|
| ||
the manufacturer’s instructions when |
|
| Air | Electrical |
| ||
installing the packer type foot valve. |
|
|
| ||||
As an alternative, an |
|
| Volume | ! WARNING | Risk of electrical | ||
Figure 4 - Horizontal Tank | Control | shock. This pump is | |||||
can be used with a driven well (Figure |
| designed for indoor installation only. | |||||
3, Illustration C). The pipe between the |
|
|
| The voltage of power supply must | |||
check valve and the water level will |
| Air |
| ||||
|
| match the voltage of the pump. All | |||||
always be under a vacuum. |
| Volume |
| ||||
|
| above ground well pumps except | |||||
Leaking joints or couplings will allow |
| Control |
| ||||
| Air Volume | SWS50BOOST have dual voltage motors | |||||
air to leak into the pipe and cause |
| Control | preset at the factory to 230 volts. The | ||||
abnormal pump operation. Make sure |
| Tubing | motors can be converted to 115 volts | ||||
to use pipe joint compound on all male | Outlet |
|
| by turning the voltage selector to the | |||
pipe threads. |
|
|
|
| desired voltage (See Figure 7). Use a | ||
DUG WELL, CISTERN, LAKE AND SPRING |
|
|
| needle nose pliers to pull the selector | |||
INSTALLATION (FIGURE 12) |
|
|
| out approximately 1/4”, rotate and | |||
1. Install a foot valve on inlet pipe and |
|
|
| then reinsert in correct position. | |||
| Hose |
|
|
| |||
lower into water. |
|
|
|
| |||
| Coupling |
|
| ||||
|
|
|
|
| |||
! CAUTION | The foot valve | Figure 5 - Vertical Tank |
|
|
| ||
should be at least |
|
|
| ||||
18” from the bottom of the well or | noise transmitted to the house |
|
| ||||
sand or sediment could be drawn into | thrugh the piping. |
| 230 V |
| |||
the system. |
| 4. Provide a hose bib (faucet) at the |
|
| |||
NOTE: When a lake is used as a water | 115 V |
| |||||
lowest point in the system to drain |
|
| |||||
supply, make sure the inlet pipe is deep |
|
| |||||
the system for service or storage. |
|
| |||||
enough to be submerged at all times. |
|
| |||||
|
|
|
|
| |||
Slope the horizontal piping upward | SHALLOW WELL PUMP WITH |
|
| ||||
toward the pump to prevent trapping |
|
| |||||
PRECHARGED STORAGE TANK |
|
| |||||
air. The pipe must be removed during |
|
| |||||
(FIGURE 6) |
|
| 230 V | ||||
winter months or protected against |
|
| |||||
|
|
|
| ||||
|
|
|
|
| |||
freezing. |
| Motor | Outlet | Priming |
|
| |
|
|
| Plug |
|
| ||
Protect the pipe from damage from |
|
| 115 V | ||||
|
|
| |||||
swimmers and boats. |
|
| Nozzle | Figure 7 - Voltage Selector | |||
| Install a screen |
|
|
|
| ||
! WARNING |
|
| Clean | Select the proper size wire and fuse | |||
around the inlet |
|
| Out | ||||
pipe to prevent the entrapment of |
|
| Drain | (Chart 3). Time delay fuses are | |||
swimmers. |
|
|
| recommended over standard fuses for | |||
SHALLOW WELL PUMP WITH |
|
| Fitting | motor circuit protection. All pump | |||
|
|
| |||||
CONVENTIONAL STORAGE TANK |
|
| motors have | ||||
(FIGURES 4 & 5) |
|
|
| overload protection that will prevent | |||
|
| 3/4 HP & 1 HP |
| ||||
1. Install air volume control on tank. |
|
|
| damage to the motor due to | |||
|
|
| overheating. |
| |||
2. Connect the copper tube from the |
|
|
|
| |||
Figure 6 - Precharged Storage Tank |
| Do not connect to | |||||
air volume control to the | ! WARNING | ||||||
uppermost 1/8” NPT opening on the |
|
|
| electric power | |||
1. Shut off the power to the pump. | supply until unit is permanently | ||||||
side of pump. Be sure the | |||||||
grounded. Connect ground wire to | |||||||
connections are tight. Leaking can | 2. Open the faucet nearest the tank | approved ground then connect terminal | |||||
cause the pump not to prime. | and allow all water to drain from | provided. |
| ||||
3. Install a valve and an isolator hose | the tank. |
| A metal underground water pipe or | ||||
between the tank and the house | 3. Measure the tank precharge at the | well casing at least 10 feet long makes | |||||
plumbing to aid in pump removal | valve stem using a tire pressure | the best ground electrode. If plastic | |||||
for servicing and for reducing the | gauge. |
| pipe or insulated fittings are used, run |
www.waynewatersystems.com
|
|
| .arcilla o roca | como tales impermeables | materiales entre | atrapada está permeables |
|
|
|
| .irrigación o | tales fines para | Puede .humano |
|
|
|
|
| lavado como | utilizada ser |
|
| .derrumbe se que | evitar para concreto | o piedra ladrillo, | con reviste se Luego | .superficial basante |
(2") cm 5,1 y | (1") cm 2,5 entre fluctúan | comunes diámetros Los | .pies) (50 m 15,25 a | menor es general lo por | profundidad La .freática | capa la de debajo |
pozos para (6") cm 15,2 doméstico uso de agua de | y (4") cm 10,2 (3"), cm 7,6 | (2"), cm 5,1 son comunes | diámetros Los .pies) (1000 | m 305 de más hasta pies | algunos entre fluctúan | profundidades Las |
. |
|
|
|
|
|
|
|
|
|
| .humano | para apta | El .techos |
|
|
|
|
| consumo | es no agua |
Figura 13 - Suministros de Agua
materiales en agua el | cuando Ocurre .tierra la de | emerge que manantial Un | MANANTIAL: (A) |
|
|
|
| (A) |
|
|
|
| ||
| ESQUISTO |
|
| LAGO, (B) ARROYO, ESTANQUE | MANANTIAL |
|
|
|
| |||||
consumo para apta es no | general lo por tratada, sea que | menos a que superficial, Agua | ESTANQUE: o ARROYO LAGO, (B) |
|
|
|
|
|
| |||||
| ACUIFERA | CAPA | TIERRA SUPERFICIAL | PERFORADO | POZO(C) | Aguade Suministros | ||||||||
.tuberíasconrevestidoportierra,la en punta profundidad unahasta | maquinariacontierralaconpantallauna con diámetro de piesvarios | enperforadohoyoUntuberíaunaacciona Se de hoyo un excavaSe | PERFORADO:POZO(E)ACCIONADO:POZO (D) EXCAVADO: POZO(C) |
| MATERIAL PERMEABLE |
| ARCILLA | POZO(E) | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| EXCAVADO |
|
|
|
|
|
|
| ARENA |
|
|
|
|
| POZO(D) ACCIONADO |
| |
losdelluviasdeagua | recolectarparaconstruido | subterráneotanqueUn | CISTERNA:(F) |
|
| FREATICA |
|
|
|
|
| CISTERNA(F) |
|
|
|
|
|
|
|
|
|
|
| ||||||
| y |
|
|
|
|
|
|
|
|
|
|
|
|
|
29 Sp