Clean Burner Tubes

BURNER TUBE CLEANING

OR REPLACEMENT (continued)

Clean Burner Tubes

You will need: A flashlight, a wire (a straightened-out coat hanger), a suitable stainless steel bristle brush, and a soft bristle brush (toothbrush).

A)Look inside each burner tube and Crossover® tube with a flashlight (1).

B)Clean any debris or blockage from the inside of the tubes with the wire (2).

C)Check spider/insect screens at the ends of the burner tubes and clean them using the soft bristle brush (3).

mCAUTION: Do not clean the spider/ insect screens with hard or sharp tools. Do not dislodge the spider/ insect screens or enlarge the screen openings.

D)Use the steel bristle brush to clean the outside of the burner tubes and the Crossover® tube. This is done to make sure all burner ports (openings) running along the length of the tubes are fully open. When cleaning burner tube 1, avoid damaging the igniter electrode by carefully brushing around it (4).

mCAUTION: Do not enlarge the burner ports when cleaning.

ANNUAL MAINTENANCE

1

2

3

4

26WWW.WEBER.COM®