Weber PL - PG. 59 57205 manual Annual Maintenance, BURNER TUBE CLEANING OR REPLACEMENT continued

Models: PL - PG. 59 57205

1 84
Download 84 pages 53.71 Kb
Page 28
Image 28
Reinstall Manifold

BURNER TUBE CLEANING

OR REPLACEMENT (continued)

Reinstall Manifold

You will need: A Phillips screwdriver, two 7/16" wrenches.

A)Align valves with burner tubes. Using two 7/16" wrenches, install bolts and nuts that secure manifold to cookbox (1).

B)With a Phillips screwdriver, install screws and washers that secure manifold to front cross brace (2). If manifold was properly reinstalled, valves will now be fully seated inside burner tubes.

mCAUTION: The burner tube openings

(3) must be positioned properly over the valve orifices (4).

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting. Refer to

CHECKING FOR GAS LEAKS.

C)Replace cookbox components (not pictured).

Reinstall Control Panel

You will need: A Phillips screwdriver.

A)Guide the two wires on back of control panel over front cross brace and down into cabinet (5).

B)Align valve stems with holes in control panel. Position top edge of control panel on tabs of frame assembly. Push control panel down into position.

C)Fasten control panel with screws.

D)Place control knobs onto valve stems.

E)Connect the wires to the igniter module. Snap wires back into wire clips on inside left panel. Refer to

“MAINTAINING THE ELECTRONIC CROSSOVER® IGNITION SYSTEM” for proper positioning.

mWARNING: Make sure that all parts are assembled and hardware is fully tightened before operating the grill.

Your actions, if you fail to follow this product warning, may cause a fire, an explosion, or structural failure resulting in serious personal injury or death as well as damage to property.

ANNUAL MAINTENANCE

3

4

1

2

5

STORAGE AND/OR NONUSE

For grills that have been stored or left unused for a while, it is important to follow these guidelines:

The gas must be turned off at the LP cylinder when the Weber® gas grill is not in use.

If storing the Weber® gas grill indoors, first DISCONNECT the gas supply and store the LP cylinder outdoors in a well-ventilated space.

Do not store a disconnected LP cylinder in a building, garage, or any other enclosed area.

If you do not disconnect the LP cylinder from the Weber® gas grill, be sure to keep both the grill and the cylinder outdoors in a well-ventilated area.

The Weber® gas grill should be checked for gas leaks and any obstructions in the burner tubes before it is used. (Refer to “ANNUAL MAINTENANCE.”)

Check that the areas under the control panel and the slide-out grease tray are free from debris that might obstruct the flow of combustion or ventilation air.

The spider/insect screens should also be checked for any obstructions. (Refer to “ANNUAL MAINTENANCE.”)

28WWW.WEBER.COM®