BURNER TUBE CLEANING

BURNER TUBE CLEANING

OR REPLACEMENT

Confirm that Grill Is Off

A)Turn gas supply off at source and disconnect gas fitting.

B)Check that all burner control knobs are in the off

(Remove Manifold) position. Check by pushing control knobs in and turning them clockwise until they stop. If they do not turn, they are already off. If they do turn, continue turning them clockwise until they stop; then they are off. If your grill has a side burner, make sure the side burner control knob is turned off.

Remove Control Panel

You will need: A Phillips screwdriver.

A)Open cabinet door. Remove igniter wires from wire clips on the inside left panel (1). Disconnect wires from igniter module inside the cabinet (2).

NOTE: Do not disconnect by pulling on wires; pull from terminals at ends of wires.

B)Remove cookbox components (3).

C)Remove control knobs (4).

D)Remove screws from the front of the control panel with a Phillips screwdriver (5).

E)Carefully lift control panel up and then pull forward and away from cookbox (6).

Remove Manifold

You will need: A Phillips screwdriver, two 7/16" wrenches.

A)With the Phillips screwdriver, remove two screws and two washers attaching manifold to front cross brace (7).

B)Using two 7/16" wrenches, remove two bolts and two nuts attaching manifold to cookbox (8). Pull manifold forward and away from burner tubes (9). Manifold will remain attached to corrugated gas line(s). Be careful not to let manifold scratch frame or door or kink the attached corrugated gas line(s).

ANNUAL MAINTENANCE

2

1

3

4

5

 

6

 

 

 

8

7

9

24WWW.WEBER.COM®