Western Digital WDBLGT0040KBK, WDBLGT0120KBK, WDBLGT0160KBK, WDBLGT0080KBK Settings, Description

Models: WDBLGT0120KBK WDBLGT0160KBK WDBLGT0040KBK WDBLGT0080KBK

1 82
Download 82 pages 55.91 Kb
Page 26
Image 26
Manual background

 

MANAGING THE WD SENTINEL SERVER (DASHBOARD)

 

 

Settings

Description

 

 

Storage

Displays storage information associated with the WD Sentinel server. The

 

WD Sentinel server holds up to four of WD’s hard drives optimized for

 

quality, reliability and performance and features RAID levels 1 or 5 to

 

enhance performance and data protection.

 

RAID is an acronym for Redundant Array of Independent Disks. With two

 

drives installed, the WD Sentinel server uses RAID 1 (mirror). With three or

 

four drives installed, the server uses RAID 5, which offers fast

 

performance by striping data across all drives. This arrangement protects

 

data by dedicating a quarter of each drive to fault tolerance, leaving three

 

quarters of the system capacity available for data storage.

 

Type: RAID level

 

Total Capacity: Maximum amount of storage space (TB) available.

 

Available Capacity: Amount of storage (TB) left available for use.

 

Alert Threshold: The percentage of storage capacity used above which

 

you receive alert notifications that the storage is approaching maximum

 

threshold.

Status: The status of the server storage may be:

Healthy–All drives are in the optimal state.

Degraded–A single drive failed; data is protected, but performance is degraded. (A failed drive must be replaced with a healthy drive as soon as possible to fully protect your server and data.)

Status of drives 1-4:The status of a drive may be:

 

 

Normal

 

 

• Failed!: Visit WD Store to replace.

 

CAUTION: Imminent failure detected. Please replace this hard drive

 

immediately.

 

 

System Temperature

Enclosure: The temperature within the server enclosure.

 

CPUs 1 & 2: The Temperature, status, and status description for each

 

CPU. (The server does not have two physical CPUs but instead uses a

 

dual core CPU. CPU 1 and CPU 2 represent the details for each core.)

 

The status may be:

 

 

Normal

 

 

Warm

 

 

Hot

 

 

Cooling Fans

The status of the server’s cooling fan may be:

 

Active

 

Inactive

 

Speed of revolutions in RPMs.

 

 

Power Supplies

The server has two power supplies. If you use both and one fails, the

1 & 2

other takes over and the WD Sentinel server remains operational. The

 

status may be:

 

Active

 

Inactive

WD SENTINEL DX4000

22

ADMINISTRATOR’S GUIDE

 

Page 26
Image 26
Western Digital WDBLGT0040KBK, WDBLGT0120KBK, WDBLGT0160KBK, WDBLGT0080KBK manual Settings, Description