2.Test Switching Commands: When the IPS-15 is powered up, the Switched AC Outlet will be set in the ON position. To test On/Off/Reboot functions, proceed as follows:

a)Reboot Outlet: To initiate a boot cycle, go to the IPS> command prompt, type /BOOT 1 and press [Enter]. Power to the Switched AC Outlet will be switched OFF. After the Boot Delay Period (Default = 5 Seconds), power to the Switched Outlet will then be switched back ON.

b)Switch Outlet OFF: To power the Switched AC Outlet OFF, go to the IPS> command prompt, type /OFF 1 and press [Enter]. Power to the Switched Outlet will be switched OFF.

c)Switch Outlet ON: To power the Switched AC Outlet ON, go to the IPS> command prompt, type /ON 1 and press [Enter]. Power to the Switched Outlet will be switched ON.

3.Exit Command Mode: When you have finished testing the IPS unit, type /X and press [Enter] to exit from the Command Mode. Note that it is recommended to always disconnect using the /X command. If the /X command is not invoked at the end of a command session, then the IPS will not exit from command mode until the No Activity Timeout feature closes the session. In this case, further access to the IPS command mode may not be allowed until the current session times out.

This completes the introductory overview of the IPS. Please proceed to Sections 4 and 5 for complete installation and configuration procedures.