Whirlpool ACE184XR0 Electrical Requirements, Window installation, Through-the-wallinstallation

Models: ACE184XR0

1 36
Download 36 pages 44.83 Kb
Page 4
Image 4
Window installation

Window installation

Window opening measurements:

26¹⁄₂" (66.1 cm) minimum to 40" (101.6 cm) maximum opening width.

20" (50.8 cm) minimum opening height.

A

B

A. 26¹⁄₂" (66.1 cm) minimum

B. 20" (50.8 cm) minimum

Through-the-wall installation

The wall opening measurements should be:

Width: 26¹⁄₂" (66.1 cm) plus twice thickness of wood used to build frame.

Height: 19³⁄₄" (50.2 cm) plus twice thickness of wood used to build frame.

Depth: 2¹⁄₂" (6.4 cm) minimum to 8" (20.3 cm) maximum.

 C C

A

B Electrical Requirements

Electrical Shock Hazard D

 

C

A. 19³⁄₄" (50.2 cm)

C. Wood thickness

B. 26¹⁄₂" (66.1 cm)

D. 2¹⁄₂" (6.4 cm) minimum to

 

8" (20.3 cm) maximum

Electrical Requirements

Plug into a grounded 3 prong outlet.WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located behind the front panel on the flange below the control panel area.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply

 

cord

Wiring requirements

115-volt (103.5 min. - 126.5 max.)

 

0-12 amps

 

15-amp time-delay fuse or circuit breaker

 

Use on single outlet circuit only.

¹⁄₄"

230-volt (207 min. - 253 max.)

 

0-12 amps

(0.6 cm)

15-amp time-delay fuse or circuit breaker Use on single outlet circuit only.

230-volt (207 min. - 253 max.)

 

0-16 amps

 

20-amp time-delay fuse or circuit breaker

 

Use on single outlet circuit only.

 

 

¹⁄₂"

230-volt (207 min. - 253 max.)

 

0-24 amps

(1.3 cm)

30-amp time-delay fuse or circuit breaker Use on single outlet circuit only.

4

Page 4
Image 4
Whirlpool ACE184XR0 manual Electrical Requirements, Window installation, Through-the-wallinstallation, C A B D