Troubleshooting 173
No Configuration for Array Accelerator Board
Description: The array accelerator board has not been configured.
Action: If the array accelerator board is present, run ACU to configure the board.
NVRAM Configuration Present, Controller not Detected
Description: EISA NVRAM has a configuration for an array controller, but no
board exists in this slot. Either a board has been removed from the system or a
board has been placed in the wrong slot.
Action: Place the array controller in the proper slot, or run the server setup utility
to reconfigure NVRAM to reflect the removal or new position.
One or More Drives is Unable to Support Redundant Controller Operation
Description: At least one drive in use does not support redundant controller
operation.
Action: Replace the drive that does not support redundant controller operation.
Other Controller Indicates Different Hardware Model
Description: The other controller in the redundant controller configuration is a
different hardware model.
Action: Be sure both controllers are using the same hardware model. If they are,
make sure the controllers are fully seated in their slots.
Other Controller Indicates Different Firmware Version
Description: The other controller in the redundant controller configuration is
using a different firmware version.
Action: Be sure both controllers are using the same firmware revision.