208 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
601-Diskette Controller Error
Audible Beeps: None
Possible Cause: Diskette controller circuitry failure occurred.
Action:
1. Be sure the diskette drive cables are connected.
2. Replace the diskette drive, the cable, or both.
3. Run Insight Diagnostics ("HP Insight Diagnostics" on page 80) and replace
failed components as indicated.
602-Diskette Boot Record Error
Audible Beeps: None
Possible Cause: The boot sector on the boot disk is corrupt.
Action:
1. Remove the diskette from the diskette drive.
2. Replace the diskette in the drive.
3. Reformat the diskette.
605-Diskette Drive Type Error.
Audible Beeps: 2 short
Possible Cause: Mismatch in drive type occurred.
Action: Run the server setup utility to set the diskette drive type correctly.