Windsor 10086130, 10086150 manual Maintenance-Batteries, Changing Batteries

Models: 10086150 10086130

1 136
Download 136 pages 7.47 Kb
Page 28
Image 28
CHANGING BATTERIES

MAINTENANCE-BATTERIES

6.Replace the battery caps, and leave them in place while charging.

7.Unplug the machine connector from the battery.

FOR SAFETY: When charging, connect the charger to the batteries before connecting the charger to the AC wall outlet. Never connect the charger to the AC wall outlet first. Hazardous sparks may result.

8.Plug the charger connector into the battery connector. Connect the charger AC plug to a wall outlet. The charger gauge should indicate that the batteries are charging.

9.When the batteries are fully charged, disconnect the charger from the AC wall outlet, then disconnect the charger from the batteries.

10.Connect the machine to the battery connector.

11.Check the electrolyte level. It should be up to the indicator ring. If necessary, add distilled water.

12.Lower recovery tank by safely disengaging the prop rod latch and slowly lowering. Replace the hose and “Y” tube connection. Replace front cover.

CHANGING BATTERIES

Stop the machine in a clean area next to the charger. Turn off machine.

FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn off machine and remove key.

1.Disconnect machine from battery pack.

2.Raise recovery tank and engage prop rod latch.

3.Disconnect main positive lead and secure cable terminals away from batteries.

4.Loosen both terminals on each jumper cable and remove one at a time.

5.Prepare a suitable site to place the batteries.

6.Attach suitable battery lifting device and lift batteries from the machine.

Batteries are a potential environmental hazard. Consult your battery supplier for safe disposal methods.

+

RED

-

 

 

 

BLK

+

RED

-

 

 

 

BLK

+

RED

-

 

 

 

BLK

REAR OF

MACHINE

4-5

86292490 VOYAGER DUO 08/20/07

Page 28
Image 28
Windsor 10086130, 10086150 manual Maintenance-Batteries, Changing Batteries