Do not use a pressure washer to clean around

Do not use a pressure washer to clean around

the brush motors. Use tap pressure only.

TO REPLACE SCRUB BRUSH MOTORS

1.With the scrub deck in the lowered position, remove the deck cover and disconnect brush motor wiring connector from harness.

2.Remove the motor and end bracket assembly from the deck.

3.Separate brush motor from end brackets.

4.Reverse to reassemble.

MAINTENANCE-SCRUB DECK

BRUSH MOTOR CARBON BRUSH

REPLACEMENT

1.Scribe alignment mark on motor barrel to motor cap. Remove two bolts.

2.Remove end cap from motor.

NOTE: Motors contain two wave washers in cap. Do not lose these.

3.Release brush from spring tension. Remove screw connecting brush wire lead to brush holder. Clean brush holder to insure free movement.

4.Retract spring and install new brush. Install connector screw and lead.

5.When all new brushes are installed. Place all in retracted position, held into brush holder by spring tension.

6.Carefully place end cap onto bearing on motor shaft.

NOTE: Use care to assure wave washer alignment.

7.With end cap in partially installed position, release all brushes to contact position with motor commutator.

NOTE: Failure to insure all brushes are released will result in motor failure.

8.Reset end cap and realign with scribe marks on motor barrel. Reinstall the two attach bolts from cap into base.

9.Maintain alignment between motor barrel base and cap.