46945 Hose Kit

Attach Hoses to Control Valve

NOTICE

If hydraulic lines are not connected as shown in the mount installation manual or tractor man- ual, the loader control valve may be damaged. A blocked outlet (RETURN) or improper hose con- nection will cause pressurized oil to enter the return circuit and damage the valve or the tractor hydraulic system.

1.Attach 90° end of hoses (2) to the IN, OUT, and PBY ports on the control valve.

2.Route hoses over hose guide (as shown in Figure 15), under right side of platform, and over right rear axle.

2.46947 Hose, 120” x 3/4 JICF x 7/8 JICF

Figure 16. Control Valve Hose Connections

Install Hydraulic Fittings and Hoses

1.Locate the hydraulic ports on the rear of the trac- tor as shown in Figure 17.

2.Remove tube and fittings from the PBY, PRESSURE, and RETURN ports.

RETURN

PRESSURE

PBY

DP3

Figure 17. Tractor Hydraulic Connections

12 Hydraulic Installation

MAN0041 (Rev. 4/4/2008)

 

 

Page 12
Image 12
Woods Equipment LU126 installation manual Hose Kit Attach Hoses to Control Valve, Install Hydraulic Fittings and Hoses