Wiring Overview
This drawing is for 12 V & 24 V systems.
For higher voltages see Prescaler use on page 44.
DC++
Fuses -
Shunt
Twisted pair cable See Detail page 13

Terminal Strip
Connections
See Detail page 14
Mounting Page 10
Removing page 11
INSTALLATION TIP:
Use appropriate strain relief to avoid damage to the connector and terminal strip on the rear of the Link 10.
TIP: For a neat and professional looking installation use plenty of:
*Nylon wire wraps
*Wire wrap anchor points.
NOTE: To limit Voltage measurement error do not exceed wire lengths shown below. Error assumes 16 AWG wire and max. power consumption.
| 0.5% Error | 72 Feet Maximum |
| 1.0% Error | 150 Feet Maximum |
12 | 3.0% Error | 450 Feet Maximum |
|
|