Advanced Functions
F03 DISPLAYORSETBATTERYTEMPERATURE
If there is no external temp sensor and F16 is OFF (factory default), this function sets ambient battery temperature used to caluculate rate corrected battery capacity which drives the LED bar graph and the Time remaining display. Feature not available on units with serial numbers prior to 05000.
DEFAULT: 20 °C | RANGE: | STEP: 1 °C |
If F16 is ON and an optional external temperature sensor is connected between Pin 6 and Pin 8 (ground), F03 will display temperature
F04 TURN ON KWHRS DISPLAY
Kilowatt hours are displayed in the Ah mode. (Note: The kWh display does not take into account Charging Efficiency. As a condition for a recalculation of the CEF and an automatic reset of amp hours to zero, 100% of the energy removed from the battery must be returned. The number in the kWh display must be zero or positive to allow a recalculation of the CEF and an automatic reset to zero. You may use this function to verify that this condition has been met.)
DEFAULT: OFF RANGE: OFF or ON
F05 USEALTERNATIVEENERGY(AE)DEFAULTS
Changes time to meet Charged Parameters to one minute from the normal five minutes. (Also consider changing Charged Current to 4%.) DEFAULT: OFF RANGE: OFF or ON
31