Advanced Functions
RESET DATA LOCK FUNC | Advanced Functions |
FUNC Allows setup of Advanced Functions.
To access the FUNC mode, SELect the FUNC mode as previously de- scribed. The letters F0i will appear in the display and the FUNC LED will be lit, indicating you are in the FUNC mode. Continue pressing the SEL button until the function you wish to set up appears. Now press SET until the desired value or mode appears. Repeat this procedure until you have set up all of the desired advanced functions. Whatever functions you have set up will become active when the display reverts to its normal mode.
F01 AUTO DISPLAY SCANNING
Automatically scans V, A, Ah, and T. Each value is displayed for four seconds. DEFAULT: OFF RANGE: OFF or ON
F02 ENHANCED SLEEP MODES
DEFAULT: ON RANGE: ON, OFF, AU (AUTOMATIC) When the Sleep Mode is ON, the Link 10's numeric display turns off after 10 minutes in order to reduce power consumption. Pressing either SET or SEL buttons returns the numeric display to operation.
When the Sleep Mode is OFF, the numeric display stays on at all times. In the special automatic sleep mode (displayed asAu), the numerics are on whenever charging or discharging exceeds 1 amp. When the rate of charge or discharge remains less than 1 amp for 10 minutes, the numeric display is turned off to conserve power. When asleep, pressing either SET or SEL reactivates the numeric display. The numeric display automatically wakes up when the rate of charge or discharge exceeds 1 amp. The Automatic Sleep Mode is ideal for electric vehicles.
DEFAULT: ON | RANGE: OFF or ON |
30