Historical Data

RESET DATA LOCK FUNC

Key Battery Data Displayed

 

DATA Key historical battery information is available through this function. Each time the SEL button is pressed while in the DATA mode the next piece of data is displayed. To see DATA, select DATA as previously described.

CEF (Displayed as E99): The Charging Efficiency Factor (CEF) is displayed. A display of E99 indicates a 99% CEF. This number sets the rate at which amp hours are counted back up during charging. This is an amp-hour CEF, not kWh efficiency. The Default setting is 90%. NOTE: If the CEF display has a u in front of it, this means the CEF has been selected by the user. See Advanced Function F06 for details.

#CEF Recalculations (Displayed as +I999): This is the number of times that the battery has been discharged more than 10% and then recharged until the Charged Parameters have been met. May be considered as the number of charge/discharge cycles the battery has experienced.

Deepest Discharge (Displayed as -i999): Shows the deepest discharge in amp hours recorded by the meter since its last RESET to factory defaults.

Average Discharge (Displayed as i999): The running average of all discharges as an amp-hour value since last RESET to factory defaults.

29