Troubleshooting
Problem | Suggestion |
No lights or display | Check Power Connections |
| Reset meter (page 28) |
No keyboard response | Check Lock is not invoked |
| Reset meter (page 28) |
Time Remaining Not | Check Battery Capacity (page 21) |
Accurate | Check Temperature Coefficient (page 32) |
| Check Peukert Exponent (page 26) |
Digital Display Dim | Clean front panel |
| (Between A and Ah lights) |
Current Polarity Reversed | Current Shunt leads reversed (page 13) |
Intermittent Operation | Corrosion or loose wires. Loosen and |
| reconnect all rear panel connections. |
| Check voltage sense and shunt wiring |
| at battery location. |
Accumulates Negative | Charge Parameters not met. Check |
Charged Parameter | |
| kWh been returned? Charging Current is |
| not passing through shunt (pages 13, 22, |
| 23, and Function F04). |
Xantrex Technology, Inc. warrants that the Link 10 will measure voltage, amperage, and amp hours within the published specifications. The Time Remaining and LED bar graph functions are complicated and require appropriate user setup and are therefore beyond the control of Xantrex and are not covered by warranty. Similarly, installation wiring and specific applications are beyond our control and are not covered by warranty. See page 52.