Low Battery Alarm
Units with serial numbers greater than 005000 allow access to an enhanced Low Battery Alarm feature. To activate this feature, change Function F14 to ON. When F14 is ON, the Link 10 displays a visual alarm when the monitored battery meets either of two conditions:
1)A settable rated compensated (Peukert)
2)Voltage remains below a settable level for 15 seconds or longer. When operating the Link 10 with the visual Low Battery Alarm function ON, three additional software functions are active. Two of these functions, F11 and F12, set the low
There are two levels of visual alarm.
Level 1: The normal display alternates with a blank Bar Graph and LO appears in the numeric display.
Level 2: Once the Level 1 alarm display is acknowledged by the operator by pressing either SET or SEL once, the Level 2 Alarm flashes the amp- hours function light while dimming the presently displayed function light. In the event amp hours are displayed, the
Special versions of the Link 10 close a circuit to ground when either Visual Alarm level is active. This circuit may be used for audible alarms, generator staring, and so forth. Because additional internal circuitry is included, this option may not be retrofitted to the Link 10 in the field.