Reset and Lock

In addition to reporting primary system values, the Link 10 is capable of many other front panel functions and will also display important historical battery data. The words below the bar graph display indicate which of these functions you are accessing. To use these functions you must read and understand the following section of this manual.

Resetting the Link 10

RESET DATA LOCK FUNC

RESET Resets amp hours to zero and resets the Link 10 to factory values.

To RESET the amp-hour display to zero, SELect the RESET function as previously described. The letters AH will appear in the display. Press and hold the SET button. After five seconds the amp-hour display will be reset to zero and the letters ALL will appear. If you continue to hold down the SET for another five seconds all variables and functions are reset to the factory defaults.

RESET DATA LOCK FUNC Front Panel Locking

LOCK Prevents user access to Set Up and Advanced Functions.

To LOCKthe Link 10, SELect the LOCK function as previously described. The letters LOC will appear in the display, indicating you are in the LOCK function. Press SET and the letters off appear, indicating the front panel is not locked. Press SET again and the letters on will appear, indicating the front panel is locked. Repeating this procedure toggles the lock off and on. The display will report off or on, indicating Lock off or on.