Lift Truck Installations

Installation of the Link 10 in lift trucks, which have the motive pack bonded to the chassis and also have a 12 V accessory battery bonded to the chassis, may use the diagram below for proper wiring of the appropriate Prescaler. The 0–100 V Prescaler is used where system voltage does not exceed 100 V at any time, including during onboard charging. In any other instance, a 500 V Prescaler must be used. If possible, install separate Anderson (SMH) connector so pack can be charged in truck if batteries are not changed. This way, battery cycles will be counted.

TO

+

 

2 A fuse. Above 250 V

 

 

 

use 500 V rated fuse. Warning: Reversing input

ANDERSON

 

 

 

 

Prescaler

 

 

Black

 

 

+

Red

 

 

voltage destroys Prescaler

 

 

HV

(Tagged)

 

 

and voids warranty.

 

 

Battery

 

 

 

 

CONNECTOR

 

-

 

 

 

 

 

 

Black

 

 

Red

 

 

 

 

 

 

 

 

 

 

(Tagged)

 

Shunt

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

Link 10

1

5 6 7 8

 

12 V

-

(-)

(-)

 

2 3 4

 

or

Acces.

 

 

Battery

Optional

 

 

 

 

24 V

 

 

 

 

DC-DC

 

 

 

 

 

+

Converter

(+)

 

 

 

 

 

 

 

 

 

 

 

This line is not used

if DC-DC converter is installed.

48