TRACE ENGINEERING (3) MENU HEADING

MENU SYSTEM

Load Start Amps

ReadyNO

If YES is displayed, it indicates that the automatic control system has started or is about to start the generator because the AC load current has reached the LOAD START AMPS setting. The automatic start is delayed by the time period set by the LOAD START DELAY MIN setting in the GEN AUTO START SETUP (12). This allows checking why the generator was automatically started.

Voltage Start

ReadyNO

If YES is displayed, it indicates that the automatic control system has started or is about to start the generator because the DC battery voltage reached one of the START VOLTS settings. The automatic start is delayed by the time period of the START VOLTS setting involved in the GEN AUTO START SETUP (12). This allows checking why the generator was automatically started.

Exercise Start

ReadyNO

If YES is displayed, it indicates that the automatic control system has started or is about to start the generator because the EXERCISE PERIOD DAYS setting has been reached. This allows checking of why the generator was automatically started.

INFORMATION DISPLAY

The following information is displayed as additional Menu Items.

Move cursor to GEN OFF to reset Generator error. If no start in 5 trys then error.

If Gen starts & runs for 5 min then stops the inverter will not attempt restart until gen auto start conditions are again satisfied. If Gen runs for more than max run time then error. Under/Over speed will cause a Sync error in 10 minutes.

TRACE ENGINEERING (3) MENU HEADING

Press reset now for defaults

Allows resetting of all menu item settings to the factory default values. This also occurs when the battery is disconnected from the inverter. The RESET TO FACTORY DEFAULTS button on the control panel will only reset the default values if it is pressed while this menu item is displayed. All factory default settings will be reset except for the TIME OF DAY (6) clock.

If the RESET TO FACTORY DEFAULTS button is pressed while in any other menu item or menu heading, only the control panel display (and remote control display) is reset, no settings will be reset. This is useful for clearing any garbled display information. This may be encountered when a remote display is initially connected or when a remote is used in a high electrical noise environment such as a vehicle application.

Revision 4.01

Displays the software revision. Used to ensure compatibility with other units when stacked, etc.

INFORMATION DISPLAY

The following information is displayed as additional Menu Items.

5916 195th St NE Arlington, WA 98223 USA

Ph 360-435-8826

Fax 360-435-2229

2001 Xantrex Technology, Inc.

Telephone: 360/435-8826

SW Series Inverter/Charger

5916 - 195th Street N. E.

Fax: 360/435-2229

Part No. 2031-5

Arlington, WA 98223

www.traceengineering.com

Rev. C: February 2001

Page

39

Page 47
Image 47
Xantrex Technology SW Series owner manual TRACE ENGINEERING 3 MENU HEADING, Page 39, Menu System, Information Display