30S400 & S600 User’s Guide

Lubrication

No lubricating agents of any kind are required on this printer. Some commercially available lubricants will damage the finish if used.

AC Power Fuse Replacement

A user-replaceable AC power fuse (see Figure 6) is located just to the left of the power on/off switch. For use with both voltage ranges, the replacement fuse is a 5x20 fast blow style rated at 5 Amp/250 VAC.

1.Before replacing the fuse, turn the AC power switch off and unplug the AC power cable.

2.To replace the fuse, insert the tip of a flathead screwdriver into the slot in the end of the fuse holder end cap.

3.Press in slightly on the end cap and turn the screwdriver slightly coun- terclockwise. This will disengage the end cap from the fuse holder and permit the removal of the fuse.

4.To install a new fuse, reverse the procedure.