Printer Diagnostics

Power-On Self Test

A Power-On Self Test (POST) is performed automatically each time the printer is turned on. This test checks for proper initialization of various electronic circuits and establishes starting parameters as those stored in the printer’s memory. During this test sequence, the front panel lights will turn on and off to insure proper operation.

At the end of this self test, only the POWER LED will remain lit. If other LEDs are also lit, refer to the troubleshooting table.

Additional Printer Self Tests

These self tests produce sample labels and provide specific information that help the operator determine the operating conditions for the printer.

Each self test is enabled by holding in a specific front panel button while turning the power switch on. Keep the button depressed until the CALIBRATE LED goes out. When the Power-On Self Test is complete, the selected printer self test will automatically start. To return to printing mode, turn off and then turn on the printer.

NOTES:

nWhen performing self tests, disconnect all communications interface cables from the printer.

nWhen canceling a self test before its actual completion, always turn the printer power switch off and back on.

nWhen performing these self tests while in the Peel-Off mode, the operator must remove the labels as they become available.

nWhen the cutter option is installed and enabled, the labels printed in these self tests should be automatically cut as they are printed.