34

Configuring Printers with WebLink

Configuring Weblink

Additional Firewall Configuration

Some firewalls do not allow the first connection attempt for a device to be HTTPS, or they require newconnections to be made periodically in order to keep the initial connections intact. The weblink test branch was provided to address issues that typically arise because the printer is an unattended device.

To configure the printer to attempt an HTTP connection anytime that the HTTPS connection drops, issue the following commands:

!U1 setvar "weblink.ip.conn1.test.location" "http://www.zebra.com/apps/linktest"

!U1 setvar "weblink.ip.conn1.test.test_on" "failure"

The weblink.ip.conn1.test.location can be any valid HTTP address. The default uses a link provided by Zebra that exists for no other purpose than to help developers test their connections to the internet. Setting weblink.ip.conn1.test.test_on to interval or both will force the printer to attempt a connection to the URL in location every weblink.ip.conn1.test.retry_interval seconds (default is 900 seconds/15 minutes).

To configure the printer to try an HTTP connection periodically, independent of the HTTPS success, issue the following commands:

!U1 setvar "weblink.ip.conn1.test.location" "http://www.zebra.com/apps/linktest"

!U1 setvar "weblink.ip.conn1.test.test_on" "interval"

!U1 setvar "weblink.ip.conn1.test.retry_interval" "900"

Difference Between Conn1 and Conn2

The printer has the ability to connect to two different servers. Connection 1 (conn1) and Connection 2 (conn2) are identical in every way in terms of their configuration. It is expected that conn2 will typically be left unmodified unless a user has an alternate server that they wish to use to configure the printer.

A typical scenario in which both connections would be used is if a user wishes to have the printer connect to both a configuration server and a data source.

Enable Logging

If your printer has trouble connecting, you may wish to enable logging. By default, logging is not enabled in order to reduce the amount of memory consumed when the Weblink feature is enabled. It is recommended that, once the Weblink feature is configured properly and is performing as expected, the logging be disabled or that a very small (less than 100) number of logging entries be permitted.

To enable logging, weblink.logging.max_entries needs to be modified. By default, it is set to zero (0), which indicates that no messages are logged. When attempting to troubleshoot connection issues, it is recommended that max_entries be set to at least 100 entries. Setting max_entries to 100 means that the 100 newest logging entries will be present in weblink.logging.entries. Older entries are discarded when the maximum number of entries is reached.

! U1 setvar "weblink.logging.max_entries" "100"

P1071336-002

1/20/15

Page 34
Image 34
Zebra Technologies P1071336-002 Additional Firewall Configuration, Difference Between Conn1 and Conn2, Enable Logging