WebLink Set/Get/Do Commands

weblink.ip.conn[12].test.test_on

weblink.ip.conn[12].test.test_on

Description This command determines when the test connection should be attempted. This assists in debugging the printer's connection to remote servers when there are issues with the main weblink connection (conn1 or conn2).

^JUF, ^JUS, ^JUN, ^JUA, and device.restore_defaults do not have any affect on this setting.

Supported Devices

iMZ 220™, iMZ 320™

QLn220™, QLn320™, QLn420™

ZT210™, ZT220™, ZT230™

Type setvar, getvar, do

Commands

Details

 

 

 

setvar

This command indicate when the test connection should be attempted.

 

Format:

 

! U1

setvar "weblink.ip.conn1.test.test_on" "value"

 

! U1

setvar "weblink.ip.conn2.test.test_on" "value"

 

Values: off,failure,interval,both

 

Default: "failure"

 

 

getvar

This command retrieves the test connection setting.

Format:

 

!

U1

getvar "weblink.ip.conn1.test.test_on"

 

!

U1

getvar "weblink.ip.conn2.test.test_on"

 

 

do

This command sets when the test connection should be attempted.

Format:

! U1 do "weblink.ip.conn1.test.test_on" "value"

! U1 do "weblink.ip.conn2.test.test_on" "value"

Values: off,failure,interval,both

Default: "failure"