80Configuration
Standard Control Panel Parameters
Table 11 • Printer Parameters (Page 8 of 25)Language/Parameter Action/Explanation
Set Printhead Life for Early WarningThis parameter appears only when Early Warning for Maintenance is enabled. Set this value to the number of inches of media that the printhead is expected to print.
Default Value: 1,000,000 inchesRange: 100 to 1,000,000 inchesTo change the value shown:
1.Press SELECT to select the parameter.
2.Press MINUSWhen the printhead reaches the set length, WARNING REPLACE HEAD appears on the LCD. If the alert function is enabled, the printer generates an alert.
1.Press SELECT to accept any changes and deselect the parameter.
Reset Printhead Life Counter for Early WarningThis parameter appears only when Early Warning for Maintenance is enabled.
To reset the printhead life counter:1.Press SELECT to select the parameter.
2.Did you replace the printhead?•If you replaced the printhead, press PLUS (+) to select YES.•If you did not replace the printhead, press MINUS3.Press SELECT to accept any changes and deselect the parameter.
ViewThis parameter displays the total length of media that the printer has printed. You can use ZPL commands to change the unit of measure for this counter. For the commands, refer to the Programming Guide for ZPL, ZBI,
This parameter displays the total length of media that the printer has printed since this parameter was last reset. You can use ZPL commands to change the unit of measure and reset this counter. For the commands, refer to the Programming Guide for ZPL, ZBI,
View
This parameter displays the total length of media that the printer has printed since this parameter was last reset. You can use ZPL commands to change the unit of measure and reset this counter. For the commands, refer to the Programming Guide for ZPL, ZBI,
|
|
|
Z Series®/RZ™ Series User Guide | 1/11/11 |