Configuration 85

Standard Control Panel Parameters

Table 11 • Printer Parameters (Page 13 of 25)

Language/Parameter Action/Explanation

Calibrate Media and Ribbon Sensor Sensitivity

Use this procedure to adjust sensitivity of media and ribbon sensors.

Important • Follow this procedure exactly as presented. All of the steps must be performed even if only one of the sensors requires adjustment. You may press MINUS (-)at any step in this procedure to cancel the process.

To perform a media and ribbon sensor calibration:

1.Press SELECT to select the parameter.

2.Press PLUS (+) to start the calibration procedure. The LOAD BACKING prompt displays.

1.Open the printhead.

2.Remove approximately 8 in. (203 mm) of labels from the backing (liner), and pull the media into the printer so that only the backing is between the media sensors.

3.If your printer has the Peel-Off, Liner Take-Up, or Rewind option, complete the following substeps:

a.Push down the peel-off mechanism release lever to open the peel assembly.

b.Feed the liner over the tear-off/peel-off bar (1) and behind the peel assembly (2). Make sure that the end of the liner falls outside of the printer.

1

2

 

 

 

1/11/11

Z Series®/RZ™ Series User Guide

79695L-003