Configuration 85
Standard Control Panel Parameters
Table 11 • Printer Parameters (Page 13 of 25)Language/Parameter Action/Explanation
Calibrate Media and Ribbon Sensor SensitivityUse this procedure to adjust sensitivity of media and ribbon sensors.
Important • Follow this procedure exactly as presented. All of the steps must be performed even if only one of the sensors requires adjustment. You may press MINUS
To perform a media and ribbon sensor calibration:
1.Press SELECT to select the parameter.
2.Press PLUS (+) to start the calibration procedure. The LOAD BACKING prompt displays.
1.Open the printhead.
2.Remove approximately 8 in. (203 mm) of labels from the backing (liner), and pull the media into the printer so that only the backing is between the media sensors.
3.If your printer has the
a.Push down the
b.Feed the liner over the
1
2
|
|
|
1/11/11 | Z Series®/RZ™ Series User Guide |