Configuration 91

Standard Control Panel Parameters

Table 11 • Printer Parameters (Page 19 of 25)

 

Language/Parameter

Action/Explanation

 

 

 

ZPL only

Set Delimiter Character

 

 

The delimiter character is a two-digit hex value used as a parameter place

 

 

 

 

marker in ZPL/ZPL II format instructions. See the Programming Guide for

 

 

ZPL, ZBI, Set-Get-Do, Mirror, and WML for more information.

 

 

Note • Do not use the same hex value for the control, format, and

 

 

delimiter character. The printer must see different characters to

 

 

work properly.

 

 

Default Value: 2C ,

 

 

Range: 00 to FF

 

 

To change the value shown:

 

 

1. Press SELECT to select the parameter.

 

 

2. Press MINUS (-)to move to the next digit position.

 

 

3. Press PLUS (+) to increase the value of the digit.

 

 

4. Press SELECT to accept any changes and deselect the parameter.

 

 

 

ZPL only

Select ZPL Mode

 

 

The printer remains in the selected mode until it is changed by this

 

 

 

 

parameter or by using a ZPL/ZPL II command. The printer accepts label

 

 

formats written in either ZPL or ZPL II, eliminating the need to rewrite any

 

 

ZPL formats that already exist. See the Programming Guide for ZPL, ZBI,

 

 

Set-Get-Do, Mirror, and WML for more information on the differences

 

 

between ZPL and ZPL II.

 

 

Default Value: ZPL II

 

 

 

 

Range: ZPL II, ZPL

To change the value shown:

1.Press SELECT to select the parameter.

2.Press PLUS (+) or MINUS (-)to toggle between the options.

3.Press SELECT to accept any changes and deselect the parameter.

 

 

 

1/11/11

Z Series®/RZ™ Series User Guide

79695L-003