Figure 10-6 Menu 21.1.3 - IPX Filter Rule

1.IPX Packet Type - Enter the IPX packet type value of the packet you wish to filter. This value should be two hex-bytes.

2.Destination/Source Network # - Enter the four hex-byte destination/source network numbers of the packet that you wish to filter.

3.Destination/Source Node # - Enter in the six hex-byte value for the destination/source node number of the packet you wish to filter.

4.Destination/Source Socket # - Enter the destination/source socket number of the packets that you wish to filter. This should be a 4-byte hex value.

5.Destination/Source Socket # Comp - You can select what comparison quantifier you wish to use to compare to the value given in Destination Socket # and Source Socket #.

6.Operation - This field is only active if one of the Socket # fields is 0452 or 0453 indicating SAP and RIP packets. There are seven options for this field which determines the operation for the IPX packet.

None.

104 Filter Configuration