Athena Technologies instruction manual Chart of Series 16C Menu System Security Levels On Next

Page 16

Menu System Overview

Figure 11. Chart of Series 16C Menu System

and Security Levels

(Continued on Next Page)

Notes:

1. It is recommended you start with the input menu.

Menu

2. Parameter labels displayed will vary, depending

Access

upon the controller’s configuration.

Key

 

Mode/

 

Enter Key

 

 

(number)

 

(number)

 

(number)

 

(number)

 

(number)

12

Image 16
Contents 16C Precautions Features IntroductionSafety Warning Contents Installation Dimensions MountingWiring Contact IdentificationMake sure that you are using Appropriate thermocouple RTDs. Connect 2-wire RTDsWire, if necessary, to minimize Lead resistance. For long runs Wire RTDs should be usedOutput Types A 120/240 Vac relay, but normally closed output 2 onlyMenu Access Key Mode/Enter KeyLower Key Raise KeyPower On Security Level, Menu System, and Operating ModeSecurity Levels and Access Restrictions Security Levels Operating Modes ManualBeen installed. Pressing the Menu Access key indexes Menu System OverviewMenu System Menu System OverviewChart of Series 16C Menu System Security Levels On Next See options manual for parameter selections Menus and Parameter DescriptionsInput Menu Display Parameter SelectionJMPØ2 Output Menu Display MenuDisplay Parameter Output Type Recommended Setting seconds Output Menu Control MenuOn/Off Output Type Parameter SelectionBelow alarm setting Setpoint. High process alarmDeviation Alarm Alarm Output Type Eter should be set to which will disable it Autotune Damping Menu Recipe Ramp/ Soak MenuPower Fail Resume Supervisor Menu Calibration Menu Options MenuAutotuning To place the controller in Autotune modeAutotuning Procedure Diagram Manual Tuning BandNumber is the correct Derivative Time SecondsPossible error codes are Error CodesDisplay Problem Actions Technical Specifications Platinum 2- and 3-wire, 100 ohms at ThermocoupleMaximum lead resistance 100 ohms For rated accuracyOrdering Codes Model Input Calibration TypeRTD Calibration Values Quick-Helps Press and hold For 3 sec + PV + Warranty Repairs Two-Year Limited WarrantyOther than those expressly stated herein, There are no BUYER’S Remedy is Limited to Either i Repair orUnit Repairs Fuse rating=100 mA Requirements250 Vpk 20 mA Glossary Applications for On/Off Control Quick Setup Instructions Series 16C Temperature Controller Configured Parameters Reference Data Page For Toll-FreeTechnical Assistance in the USA Call Toll Free