Athena Technologies 16C instruction manual Dimensions, Mounting

Page 6

Dimensions

Figure 2. Case Dimensions

 

2.100"

0.717"

 

(53.3mm)

 

 

(8.21 mm)

 

O1

PV

 

O2

2.100"

A1

 

F1A2

 

(53.3mm)

SV

 

F2

 

4.654" (118.21mm) 3.937"

(100 mm)

1.750"

(44.5 mm)

Prior to mounting the Series C in your panel, make sure that the cutout opening is of the right size, 1.771” x 1.771” (45

mmx 45 mm), and deburred to enable a smooth fit. A mini- mum of 4” (100 mm) of depth behind the panel is required.

Mounting

When properly installed through a NEMA enclosure, the integrity of the enclosure will be maintained and will remain “Watertight.”

Figure 3. Series C Mechanical Components

Insert the Series C through the front panel cutout and slide the mounting collar back onto the unit from behind the panel. Push the mounting collar up tight to the back of the mounting panel.

Bezel

Case Clip

 

Grips

 

Gasket

Customer Panel

2

Image 6
Contents 16C Precautions Features Introduction Safety Warning Contents Installation Dimensions MountingWiring Contact IdentificationWire, if necessary, to minimize Make sure that you are using Appropriate thermocoupleRTDs. Connect 2-wire RTDs Lead resistance. For long runs Wire RTDs should be usedOutput Types A 120/240 Vac relay, but normally closed output 2 onlyLower Key Menu Access KeyMode/Enter Key Raise KeyPower On Security Level, Menu System, and Operating ModeSecurity Levels and Access Restrictions Security LevelsOperating Modes ManualBeen installed. Pressing the Menu Access key indexes Menu System OverviewMenu System Menu System OverviewChart of Series 16C Menu System Security Levels On Next See options manual for parameter selections Menus and Parameter DescriptionsInput Menu Display Parameter SelectionJMPØ2 Display Menu Output MenuDisplay Parameter Output Type Recommended Setting seconds Output Menu Control MenuOn/Off Output Type Parameter SelectionSetpoint. High process alarm Below alarm settingDeviation Alarm Alarm Output Type Eter should be set to which will disable it Autotune Damping Menu Recipe Ramp/ Soak MenuPower Fail Resume Supervisor Menu Calibration Menu Options MenuAutotuning To place the controller in Autotune modeAutotuning Procedure Diagram Number is the correct Derivative Manual TuningBand Time SecondsError Codes Possible error codes areDisplay Problem Actions Technical Specifications Maximum lead resistance 100 ohms Platinum 2- and 3-wire, 100 ohms atThermocouple For rated accuracyOrdering Codes Model Input Calibration TypeRTD Calibration Values Quick-Helps Press and hold For 3 sec + PV + Other than those expressly stated herein, There are no Warranty RepairsTwo-Year Limited Warranty BUYER’S Remedy is Limited to Either i Repair orUnit Repairs Requirements Fuse rating=100 mA250 Vpk 20 mA Glossary Applications for On/Off Control Quick Setup Instructions Series 16C Temperature Controller Configured Parameters Reference Data Page For Toll-FreeTechnical Assistance in the USA Call Toll Free