Menus and Parameter

Descriptions

 

Menus and Parameters

 

 

 

Input

Used to select sensor-related parameters, such as input type,

 

limits, and scaling.

Display

Used to set or change decimal position and display units.

Output

Used to specify output usage, control methods, and alarms.

Control

Used to select parameters associated with the control methods.

Alarm

Used to select alarm parameters .

 

Note: This menu is also functional for controllers not

 

equipped with alarm hardware; however, alarm indication

 

will be only visual via the A1 and A2 LEDs on the front panel.

Tune

Used to set the autotune damping parameter.

Recipe

Used to set ramp and soak parameters.

Supervisor

Used to set fail-safe and supervisory parameters.

Calibration

Used to recalibrate input.

Option

Used to select installed option.

Communications

(Option) Used to set serial communications parameters.

Contact/Digital

 

 

Input

(Option) Used to select switch input functions.

Remote Analog

 

 

Setpoint

(Option) Used to enter remote analog setpoint parameters.

Auxiliary Output

(Option) Used to set auxiliary output parameters.

14

Image 18
Contents 16C Precautions Features IntroductionSafety Warning Contents Installation Dimensions MountingWiring Contact IdentificationWire, if necessary, to minimize Make sure that you are using Appropriate thermocoupleRTDs. Connect 2-wire RTDs Lead resistance. For long runs Wire RTDs should be usedOutput Types A 120/240 Vac relay, but normally closed output 2 onlyLower Key Menu Access KeyMode/Enter Key Raise KeyPower On Security Level, Menu System, and Operating ModeSecurity Levels and Access Restrictions Security LevelsOperating Modes ManualBeen installed. Pressing the Menu Access key indexes Menu System Overview Menu System Menu System OverviewChart of Series 16C Menu System Security Levels On Next See options manual for parameter selections Menus and Parameter DescriptionsInput Menu Display Parameter SelectionJMPØ2 Display Menu Output MenuDisplay Parameter Output Type Recommended Setting seconds Output Menu Control MenuOn/Off Output Type Parameter SelectionSetpoint. High process alarm Below alarm settingDeviation Alarm Alarm Output Type Eter should be set to which will disable it Autotune Damping Menu Recipe Ramp/ Soak MenuPower Fail Resume Supervisor Menu Calibration Menu Options MenuAutotuning To place the controller in Autotune modeAutotuning Procedure Diagram Number is the correct Derivative Manual TuningBand Time SecondsError Codes Possible error codes areDisplay Problem Actions Technical Specifications Maximum lead resistance 100 ohms Platinum 2- and 3-wire, 100 ohms atThermocouple For rated accuracyOrdering Codes Model Input Calibration TypeRTD Calibration Values Quick-Helps Press and hold For 3 sec + PV + Other than those expressly stated herein, There are no Warranty RepairsTwo-Year Limited Warranty BUYER’S Remedy is Limited to Either i Repair orUnit Repairs Requirements Fuse rating=100 mA250 Vpk 20 mA Glossary Applications for On/Off Control Quick Setup Instructions Series 16C Temperature Controller Configured Parameters Reference Data Page For Toll-FreeTechnical Assistance in the USA Call Toll Free