Athena Technologies 16C instruction manual Requirements, Fuse rating=100 mA, Vpk 20 mA

Page 42

IEC

Requirements

USE OF THIS EQUIPMENT IN A MANNER NOT SPECIFIED BY

THE MANUFACTURER MAY IMPAIR PROTECTION PROVIDED

BY THE EQUIPMENT!

The maximum supply current is line voltage dependent:

230 mA for a 24 Vac/dc input

fuse rating=700 mA

60 mA for an 85 -250 Vac input

fuse rating=100 mA

Output Specifications

 

 

Output Type

Max current

Voltage

Leakage

B

5 A

250 Vac

1000 M ohms

T

1 A

250 Vpk

1 mA

S

20 mA

5 V

NA

CLEANING INSTRUCTIONS

1.Remove power from the unit prior to any cleaning operation.

2.Use a cotton cloth to gently and sparingly apply isopropyl alcohol only. Do not use cleaners or other solvents as they may damage the unit.

3.Allow the unit to dry completely prior to reapplying power.

38

Image 42
Contents 16C Precautions Features IntroductionSafety Warning Contents Installation Dimensions MountingWiring Contact IdentificationWire, if necessary, to minimize Make sure that you are using Appropriate thermocoupleRTDs. Connect 2-wire RTDs Lead resistance. For long runs Wire RTDs should be usedOutput Types A 120/240 Vac relay, but normally closed output 2 onlyLower Key Menu Access KeyMode/Enter Key Raise KeyPower On Security Level, Menu System, and Operating ModeSecurity Levels and Access Restrictions Security LevelsOperating Modes ManualBeen installed. Pressing the Menu Access key indexes Menu System OverviewMenu System Menu System OverviewChart of Series 16C Menu System Security Levels On Next See options manual for parameter selections Menus and Parameter DescriptionsInput Menu Display Parameter SelectionJMPØ2 Display Menu Output MenuDisplay Parameter Output Type Recommended Setting seconds Output Menu Control MenuOn/Off Output Type Parameter SelectionSetpoint. High process alarm Below alarm settingDeviation Alarm Alarm Output Type Eter should be set to which will disable it Autotune Damping Menu Recipe Ramp/ Soak MenuPower Fail Resume Supervisor Menu Calibration Menu Options MenuAutotuning To place the controller in Autotune modeAutotuning Procedure Diagram Number is the correct Derivative Manual TuningBand Time SecondsError Codes Possible error codes areDisplay Problem Actions Technical Specifications Maximum lead resistance 100 ohms Platinum 2- and 3-wire, 100 ohms atThermocouple For rated accuracyOrdering Codes Model Input Calibration TypeRTD Calibration Values Quick-Helps Press and hold For 3 sec + PV + Other than those expressly stated herein, There are no Warranty RepairsTwo-Year Limited Warranty BUYER’S Remedy is Limited to Either i Repair orUnit Repairs Requirements Fuse rating=100 mA250 Vpk 20 mA Glossary Applications for On/Off Control Quick Setup Instructions Series 16C Temperature Controller Configured Parameters Reference Data Page For Toll-FreeTechnical Assistance in the USA Call Toll Free