Athena Technologies 16C instruction manual Technical Specifications

Page 34

Technical

Specifications

Operating Limits

 

Ambient Temperature

32°F to 140°F (0°C to 60°C)

Relative Humidity Tolerance

90%, Non-Condensing

Power

100 to 250 V

 

50/60 Hz (Single-Phase)

 

100 to 250 Vdc

 

24 Vac/dc

Power Consumption

Less than 6 VA

Performance

 

Accuracy

±0.20% of Full Scale

 

(±0.10% Typical), ±1 Digit

Setpoint Resolution

1 Count / 0.1 Count

Repeatability

±1 Count

Temperature Stability

5 µV /°C (Maximum)

TC Cold-End Tracking

0.05°C /°C Ambient

Noise Rejection

>100 dB Common Mode,

 

>70 dB Series Mode

Process Sampling

10 Hz (100 ms)

Control Characteristics

 

Setpoint Limits

Automatically Adjust to

 

Selected TC/RTD

Alarms

Adjustable for High/Low;

 

Selectable Process, Deviation,

 

or Band Alarms

Proportional Band

1 to Span of Sensor

Integral

0 to 9600 Seconds

Derivative

0 to 2400 Seconds

Cycle Time

200 ms; 1 to 120 sec

Control Hysteresis

1 to Span of Sensor

Autotune

Operator Initiated from

 

Front Panel

Manual Control

Operator Initiated from

 

Front Panel

Mechanical Characteristics

 

Display

Dual, 4-digit 0.36” (9.2 mm)

 

LED display

 

Process Value: Orange

 

Setpoint Value/Menu: Green

Numeric Range

-1999 to 9999

Front-Panel Cutout

1.771” x 1.771”

 

(45 mm x 45 mm)

Depth Behind Panel

3.937” (100 mm)

Front Panel Rating

NEMA 4X

Operating Temperature

32 to 140° F (0 to 60° C)

Humidity Conditions

90% R.H. max.,

 

non-condensing

Parameter Retention

Solid-state, non-volatile

 

memory

Connections

Input and output via barrier

 

strip with locking terminals

Contacts

Twin bifurcated

30

Image 34
Contents 16C Precautions Features IntroductionSafety Warning Contents Installation Dimensions MountingWiring Contact IdentificationWire, if necessary, to minimize Make sure that you are using Appropriate thermocoupleRTDs. Connect 2-wire RTDs Lead resistance. For long runs Wire RTDs should be usedOutput Types A 120/240 Vac relay, but normally closed output 2 onlyLower Key Menu Access KeyMode/Enter Key Raise KeyPower On Security Level, Menu System, and Operating ModeSecurity Levels and Access Restrictions Security LevelsOperating Modes ManualBeen installed. Pressing the Menu Access key indexes Menu System OverviewMenu System Menu System OverviewChart of Series 16C Menu System Security Levels On Next See options manual for parameter selections Menus and Parameter DescriptionsInput Menu Display Parameter SelectionJMPØ2 Output Menu Display MenuDisplay Parameter Output Type Recommended Setting seconds Output Menu Control MenuOn/Off Output Type Parameter SelectionBelow alarm setting Setpoint. High process alarmDeviation Alarm Alarm Output Type Eter should be set to which will disable it Autotune Damping Menu Recipe Ramp/ Soak MenuPower Fail Resume Supervisor Menu Calibration Menu Options MenuAutotuning To place the controller in Autotune mode Autotuning Procedure Diagram Number is the correct Derivative Manual TuningBand Time SecondsPossible error codes are Error CodesDisplay Problem Actions Technical Specifications Maximum lead resistance 100 ohms Platinum 2- and 3-wire, 100 ohms atThermocouple For rated accuracyOrdering Codes Model Input Calibration TypeRTD Calibration Values Quick-Helps Press and hold For 3 sec + PV + Other than those expressly stated herein, There are no Warranty RepairsTwo-Year Limited Warranty BUYER’S Remedy is Limited to Either i Repair orUnit Repairs Fuse rating=100 mA Requirements250 Vpk 20 mA Glossary Applications for On/Off Control Quick Setup Instructions Series 16C Temperature Controller Configured Parameters Reference Data Page For Toll-FreeTechnical Assistance in the USA Call Toll Free