Athena Technologies 16C instruction manual Supervisor Menu

Page 28

Recipe (Ramp/ Soak) Menu

For Ramp Events and Soak Events to be employed, Alarm 1 or Alarm 2 must be set for

event usage in the Alarm Menu.

Supervisor Menu

The Failsafe State is only enforced when a problem is detected with the process input. It is not reli- ably enforceable in instances of internal circuitry failure such as EEPROM problems.

Output % High Limits are ignored when the unit enters a Failsafe State.

NOTE: The following seven parameters are only available when multi-step ramp is selected.

Display Parameter

Selection

Recycle Number

0-99,

(Recipe Executions)

 

Power Fail Resume

Off

 

On

Ramp Times 1-8

0-9999 mins.

Ramp Events 1-8

Alarm 1 On

 

Alarm 1 Off

 

Alarm 2 On

 

Alarm 2 Off

 

Disabled

Soak Levels 1- 8

Display Units, FS

Soak Times 1-8

0-9999 mins.

Soak Events 1-8

Alarm 1 On

 

Alarm 1 Off

 

Alarm 2 On

 

Alarm 2 Off

 

Disabled

Display Parameter

Selection

Output 1

0 to 100%

Failsafe State

of output

Output 2

0 to 100%

Failsafe State

of output

Loop Break Time

Off, 4-9600 sec

Highest Reading

n/a

Lowest Reading

n/a

Load Default

 

Parameters

 

Choosing “Yes” to Load Default Parameters resets all menu parameters to factory settings.

24

Image 28
Contents 16C Precautions Features IntroductionSafety Warning Contents Installation Dimensions MountingWiring Contact IdentificationMake sure that you are using Appropriate thermocouple RTDs. Connect 2-wire RTDsWire, if necessary, to minimize Lead resistance. For long runs Wire RTDs should be usedOutput Types A 120/240 Vac relay, but normally closed output 2 onlyMenu Access Key Mode/Enter KeyLower Key Raise KeyPower On Security Level, Menu System, and Operating ModeSecurity Levels and Access Restrictions Security LevelsOperating Modes ManualBeen installed. Pressing the Menu Access key indexes Menu System OverviewMenu System Menu System OverviewChart of Series 16C Menu System Security Levels On Next See options manual for parameter selections Menus and Parameter DescriptionsInput Menu Display Parameter SelectionJMPØ2 Output Menu Display MenuDisplay Parameter Output Type Recommended Setting seconds Output Menu Control MenuOn/Off Output Type Parameter SelectionBelow alarm setting Setpoint. High process alarmDeviation Alarm Alarm Output Type Eter should be set to which will disable it Autotune Damping Menu Recipe Ramp/ Soak MenuPower Fail Resume Supervisor Menu Calibration Menu Options MenuAutotuning To place the controller in Autotune modeAutotuning Procedure Diagram Manual Tuning BandNumber is the correct Derivative Time SecondsPossible error codes are Error CodesDisplay Problem Actions Technical Specifications Platinum 2- and 3-wire, 100 ohms at ThermocoupleMaximum lead resistance 100 ohms For rated accuracyOrdering Codes Model Input Calibration TypeRTD Calibration Values Quick-Helps Press and hold For 3 sec + PV + Warranty Repairs Two-Year Limited WarrantyOther than those expressly stated herein, There are no BUYER’S Remedy is Limited to Either i Repair orUnit Repairs Fuse rating=100 mA Requirements250 Vpk 20 mA Glossary Applications for On/Off Control Quick Setup Instructions Series 16C Temperature Controller Configured Parameters Reference Data Page For Toll-FreeTechnical Assistance in the USA Call Toll Free