Generac 004373-2, 004626-1, 004626-1, 004373-2 owner manual Description QTY, Assembly Cover Access

Page 44

Section 7 — Exploded Views and Parts Lists

(Model Nos. 004373-2 & 004626-1) Guardian Liquid-cooled 40 kW Generators

Compartment – Drawing No. 0D8992

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

23

 

 

 

 

 

29

 

 

 

 

 

25

 

 

 

32

 

 

 

 

 

 

 

 

 

 

33

 

 

 

 

 

 

 

313044

 

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

43

39

15

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

11

 

 

 

 

36

 

 

 

 

 

11

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

35

 

10

42

 

 

 

4

 

 

 

 

 

 

 

 

 

3

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

16

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

3

4

1

5

 

 

19

18

 

 

 

 

 

 

 

 

11

 

6

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

BASE

 

 

 

 

 

 

 

 

 

 

 

FRAME

 

 

 

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

1

0C3594

10

ASSEMBLY M6 HINGE

 

 

 

24

0C4066 (A)

1

DUCT BOTTOM

 

3

0A3359

40

SCREW BHSC M6-1.0 X 16 SS

 

25

0C4067 (A)

1

DUCT FRONT PANEL

4

0A3360

40

SHAKEPROOF INT M6 SS

 

 

26

0C4117 (A)

1

DUCT FRONT TOP RH

5

0C2522 (A)

5

DOOR SMALL STD. WELD

 

 

28

0C2634A

1

ASSEMBLY COVER ACCESS

6

0C2527 (A)

1

CORNER POST LH REAR

 

 

29

0C2454

76

SCREW TH-FRM M6-1X16 N WA Z/JS

7

0C2528 (A)

1

CORNER POST RH REAR

 

 

30

022129

2

WASHER LOCK M8-5/16

8

0C2535 (A)

1

CORNER POST LH FRONT

 

 

31

042907

2

SCREW HHC M8-1.25 X 16 G8.8

9

0C2536 (A)

1

CORNER POST RH FRONT

 

32

022473

15

WASHER FLAT M6-1/4 ZINC

10

0C2547 (A)

2

REAR BRACE TOP & BOTTOM

 

33

022097

1

WASHER LOCK M6-1/4

11

0C2550 (A)

4

SIDE BRACE TOP & BOTTOM

 

34

022127

1

NUT HEX 1/4-20 STEEL

12

0C2555 (A)

2

SIDE SUPPORT

 

 

 

35

0A9881

49.1 FT.

GASKET DOOR RUBBER

13

0C2560 (A)

1

ROOF ONE-PIECE WLDMT

 

 

36

0C3393

2

SCREW SHOULDER

15

0D7904 (A)

1

FRONT BRACE TOP

 

 

 

39

0C3400 (A)

1

COVER EXHAUST HOLE

16

0C2633

5

PLATE STRIKER

 

 

 

42

0C3397

4

FASTENER RATCHET

17

0C6749

20

SCREW PPHM M4-0.7 X 12 SS

 

43

066760

39-3/8"

STRIP SEALANT 1/8 X 1

18

060069

5

PADDLE HANDLE LOCK

 

 

 

44

022145

2

WASHER FLAT 5/16 ZINC

19

0C6748

20

NUT LOCK HEX M4-0.7 SS NYL INS

 

 

 

 

 

20

080490

20

WASHER FLAT #8 SS

 

 

 

 

OPTIONAL COMPARTMENT MATERIALS:

21

087233

5

RIVET POP 3/16 X 1/4

 

 

 

 

ALL P/N'S WITH AN "A" SUFFIX INDICATE

22

0C4065 (A)

1

DUCT FRONT LH

 

 

 

 

ALUMINUM MATERIAL OPTION.

 

23

0C4064 (A)

1

DUCT FRONT RH

 

 

 

 

 

 

 

 

42 Generac® Power Systems, Inc.

Image 44
Contents Power SYSTEMS, INC Introduction Authorized Dealer LocationSafety Rules General Information InstallationMaintenance Section Installation Drawings 56-57 Warranty Back CoverGeneral Hazards Electrical Hazards Prepackaged Transfer Switch UNPACKING/INSPECTIONGenerator Generator AC Connection SystemsEngine Protective Devices SpecificationsMain Circuit Breaker Fuel Requirements Recommendations Generator and Load CompatibilityEngine Conversion to LP GAS VaporAIR Fuel Ratio Controller CoolantEmissions Control System Standby Generator Installation Basic Standby Electric SystemNfpa Standards Other Published StandardsTransfer Switch Start Signal Connections Pre-Packaged Type SwitchGTS Type Engineered Switch Emergency Circuit Isolation MethodVented Batteries Battery InstallationPreparation Before START-UP Prior to Initial START-UP Using the AUTO/OFF/MANUAL Switch OFF Position Manual PositionAutomatic Transfer Operation Sequence of Automatic OperationWeekly Exercise Cycle Checking the Engine OIL LevelOil and Filter Change Procedure Changing the Engine AIR CleanerChanging the Engine OIL and Filter Engine Oil RecommendationsBattery Maintenance Spark PlugsMiscellaneous Maintenance Cleaning the GeneratorOverload Protection for Engine DC Electrical System DC FuseReturn To Service OUT of Service ProcedureRemoval From Service Service Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Section Generac Generac Power Systems,Inc Electrical Data Electrical Data Electrical Data Wiring Diagram Customer Connection Power Systems Inc HRSPart NO. QTY. Description Generators Part NO. QTY Description Part NO.QTY Description QTY Description 4640 31 33 Part NO.QTY. Description Washer Flat 3/8-M10 ZincExploded Views and Parts Lists Flywhl 4.3L GM SAE Stator Leads Scrolldetail To Engine Flywheel QTY Description Part NO. QTY Assembly Cover Access Description QTYRadiator Copper Brass Gasket Carburetor Adaptor Gasket Carb Impco QTY. Description To CarburetorSupport Solenoid NAT GAS QTY. Description To Starter Solenoid RED Black To Engine Block ALT Leads Sensing Wire Siemens FD 3 Pole QTY Description Exploded Views and Parts Lists Part NO. QTY. Description Muffler 2-1/2 INLET/OUTLET Guardian Liquid-cooled 40 kW Generators Installation Drawings 12V Battery see Note Lifting EYE Places Warranty Schedule This Warranty Shall not Apply to the Following