Briggs & Stratton 30235 When adding or draining fuel, When starting equipment

Page 5

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

When adding or draining fuel:

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

When starting equipment:

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

When operating equipment:

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

When transporting or repairing equipment:

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

When storing fuel or equipment with fuel in tank:

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

WARNING

Unintentional sparking can result in fire or electric shock.

When adjusting or making repairs to your generator:

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

When testing for engine spark:

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

NOTICE

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See Don’t Overload Generator.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

NOTICE

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or contact Briggs and Stratton.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

3

Image 5
Contents Watts Revision Serial Number Engine Model Number Date Purchased Where to Find UsTable of Contents Hazard Symbols and Meanings Safety RulesWhen starting equipment When adding or draining fuelWhen operating equipment When transporting or repairing equipmentShipment Contents AssemblyInstall Wheel Kit Equipment DescriptionAdd Engine Oil When adding fuelAdd Fuel Fuel must meet these requirementsSystem Ground Connecting to a Building’s Electrical SystemGenerator Location Special RequirementsFeatures and Controls Nema L14-30 ReceptaclesGenerator Adapter Cord Set 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationStopping the Engine Connecting Electrical LoadsDon’t Overload Generator Power ManagementCapacity ExampleMaintenance Schedule MaintenanceGeneral Recommendations Emissions ControlCleaning Generator MaintenanceOil Oil RecommendationsChanging Engine Oil Checking Oil LevelAdding Engine Oil Clean Spark Arrester Screen Service Air CleanerService Spark Plug Clean and inspect the spark arrester as follows Carburetor AdjustmentEngine Air Cooling System Check Valve ClearanceStorage Troubleshooting Replacement Parts SpecificationsMaintenance Items Engine Technical InformationLength of Coverage Owner’s Warranty ResponsibilitiesWarranted Parts Claims and Coverage Exclusions Maintenance Consequential CoverageNo Charge Warranty Period This page reserved Dónde encontrarnos Reglas de seguridad Resolución de problemas Especificaciones GarantíasMontaje Controles y característicasSímbolos de peligro y sus significados Normas de seguridadCuando ponga en funcionamiento el equipo Cuando anada combustible o vacíe el depósitoCuando opere el equipo Cuando transporte o repare el equipoDescripción del equipo MontajeDesembalaje del generador Contenido de la cajaAgregue combustible Agregar aceite al motorCuando anada combustible Gran altitudConexión al sistema eléctrico de un edificio Tierra del sistemaUbicación del generador Requisitos EspecialesControles y características del generador Tomas eléctricas dobles de 120 V CA y 20 a Tomas eléctricasDispositivo de seguridad de 120/240 V, 30 a Juego de cables del adaptador del generadorEncienda el motor OperandoParada del motor Conexión de cargas eléctricasCapacidad No sobrecargar el generadorEjemplo Control de la energíaPlan de mantenimiento MantenimientoRecomendaciones Generales Control de emisionesLimpieza Mantenimiento del GeneradorAceite Recomendaciones sobre el aceiteCambio de Aceite del Motor Comprobación del Nivel de AceiteAdición de Aceite del Motor Limpie la Pantalla Apagachispas Servicio del depurador de aireServicio del bujía Comprobación de holgura de la válvula Sistema de refrigeración de aireAjuste del Carburador Limpie e inspeccione el apagachispas de la siguiente maneraAlmacenamiento Problemo Causa Accion Resolución de problemasPotencia Nominal Información Técnica Sobre el MotorEspecificaciones del Generador Especificaciones del MotorDuración de la cobertura Responsabilidades de la garantía del propietarioPiezas garantizadas Solicitudes y exclusiones de cobertura Servicio gratuitoMantenimiento Cobertura de daños derivadosPeríodo DE Garantía

30235 specifications

The Briggs & Stratton 30235 is a powerful and efficient portable generator designed to provide reliable backup power. Ideal for homeowners and recreational users alike, this model boasts a range of features and technologies that enhance its performance and usability.

One of the standout features of the Briggs & Stratton 30235 is its 306cc engine, which delivers 7,000 starting watts and 5,500 running watts. This robust power output ensures that essential appliances, tools, and devices can be effectively supported during power outages or when on outdoor adventures. The generator is equipped with a durable 4-gallon metal fuel tank, providing up to 13 hours of run time at 50% load, which means users can count on extended operation without frequent refueling.

The generator employs a reliable and user-friendly design, featuring an easy-to-read LED display that provides important information such as power output and operational status. Additionally, it includes an automatic low oil shutdown feature, which protects the engine from damage by shutting down the unit when oil levels are too low. This functionality not only prolongs the life of the generator but also assists users in maintaining optimal performance.

For enhanced portability, the Briggs & Stratton 30235 comes with a built-in handle and never-flat wheels, making it easy to transport and position wherever needed. Its compact footprint allows it to be stored without taking up excessive space, making it an ideal choice for those with limited storage options.

The generator also features multiple outlets, including 120V 20A NEMA 5-20R duplex receptacles and a 120/240V 30A L14-30R lockable receptacle. This versatility allows users to connect a variety of devices and appliances, enhancing its usability for different applications, from home backup to camping trips.

In terms of safety, the Briggs & Stratton 30235 includes circuit protection to prevent overloading, ensuring that connected devices are protected. Moreover, it runs quietly compared to many other generators in its class, making it suitable for use in residential areas without causing a disturbance.

Overall, the Briggs & Stratton 30235 combines power, portability, and practicality, making it a top choice for those in need of reliable backup power or portable energy solutions. With its thoughtful design and advanced features, this generator stands out as a dependable companion for any situation that requires consistent electrical support.